After the appliance is plugged in

• Check that the plug is inserted correctly

and the power button is pressed,

and that the power is switched on.

no indicators are lit

• Where fitted check the plug fuse.

The power button indicator lights

• Check that pan is present

up, but heating does not start

• Check suitability of the pan

when power control is adjusted

• Check that pan is centrally located

 

 

Heating stops suddenly

• Check power supply to the appliance

during operation

• Check the air entry or the air vent is

 

not blocked

 

• Check the timing period has not ended

 

• Check the appliance has not overheated

 

or entered error mode – unplug, allow to

 

cool and try again later

 

 

In timer mode, the timer is set and

• Increase the power with the power

the on/off button is flashing but

control

heating does not begin.

 

 

 

Failure codes occur:

• Appliance may have overheated/boiled

E:03 E:06

dry. Unplug the appliance, allow to cool

 

and try again later

E:07 E:08

• Fluctuation in mains supply. Unplug the

 

appliance, allow to cool and try again

 

later

 

 

E:01 E:02 E:04 E:05 E:0b E:0C

• Send it to a service facility for repair