SCAN-3

PROGRAM SCAN

Program Scan is identical to VFO Scan except that you select a
frequency range for the scan.

Setting Scan Limits

You can store up to 10 scan ranges in Memory channels L0/
U0 to L9/U9.
1 Press [VFO].
2 Select your desired band.
3 Rotate the Tuning control to select your desired
frequency for the lower limit.
4 Press [F].
A memory channel number appears and blinks.
5 Rotate the Tuning control to select a channel from L0 to
L9.
6 Press [M.IN] to set the channel number.
The lower limit is stored in the channel.
7 Rotate the Tuning control to select your desired
frequency for the lower limit.
8 Press [F].
9 Rotate the Tuning control to select a matching channel
number from U0 to U9.
For example, if you select channel L3 in step 5, select
channel U3 here.
10 Press [M.IN] to set the channel number.
The upper limit is stored in the channel.

To confi rm the stored scan limits, press [MR],

then select the L and U channels.

Note:
The lower limit must be lower in frequency than the upper limit.
The lower and upper frequency step sizes must be equal.
The lower and upper limits must be selected on the same band.

Using Program Scan

1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select a frequency within
your desired scan range.
4 Press [VFO] (1s).
Scan starts at the current frequency.
The 1 MHz decimal blinks while scanning is in progress.
To reverse the scan direction, turn the Tuning control
clockwise (upward scan) or counterclockwise (downward
scan). You can also press microphone [UP]/ [DWN].
5 To quit Program Scan, press [VFO] again.
Note:
If the step size differs between the lower limit and upper limit, VFO
scan will begin instead of Program Scan.
If the current VFO frequency is within more than one Program Scan
range, the range stored in the smallest channel number is used.

MHz SCAN

MHz Scan monitors a 1 MHz segment of the band, using the
current frequency step size. The current 1 MHz digit determines
the limits of the scan. For example, if the current frequency is
145.400 MHz, then the scan range would be from 145.000 MHz
to 145.995 MHz (the exact upper limit depends on the current
frequency step size).
1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select a frequency within your
desired 1 MHz range.
4 Press and hold the Tuning control for 1 second to start
scanning.
Scan starts at the current frequency.
The 1 MHz decimal blinks while scanning is in progress.
To reverse the scan direction, turn the Tuning control clockwise
(upward scan) or counterclockwise (downward scan). You can
also press microphone [UP]/ [DWN].
5 To quit MHz Scan, press the Tuning control again.

CALL SCAN

Use Call Scan to monitor both the Call channel and either the
currently selected VFO frequency or the currently selected
Memory channel.
1 Select your desired VFO frequency or Memory channel.
2 Press [CALL] (1s) to start Call Scan.
The 1 MHz decimal blinks while scanning is in progress.
When scanning a Memory channel, the Call channel on the
same band as the selected Memory channel is used for scan.
3 To quit Call Scan, press [CALL] again.
Note: The Memory channel selected is scanned even if it has been locked out
of scan.