PACKET-6

Command Name Short Description Parameter Default
PPERSIST PP Causes the TNC to use the PERSIST/SLOTTIME method
when ON, or the DWAIT method when OFF. ON/ OFF ON
RAMTEST RAMTEST Checks the RAM after clearing it. −−
READ R Specifi es one or more message numbers to be read from the
TNC mailbox. −−
RESET RESET Restores the default status for all the commands. −−
RESPTIME RES Specifi es the acknowledgment packet transmission delay.
The unit of the parameter is 100 milliseconds. 0 ~ 250 5
RESTART RESTART Causes the TNC to function as if it is switched OFF then ON. −−
RETRY RE Specifi es the number of transmission retries. 0 ~ 15 10
ROUTE ROU When ON and receiving a packet forwarded by a PBBS,
leaves the included route information. ON/ OFF ON
SENDPAC SE Specifi es a character which forces a packet to be sent. 0 ~ $7F $0D
SLOTTIME SL
Specifi es the period of random number generation intervals
for the PERSIST/SLOTTIME method. The unit of the
parameter is 10 milliseconds.
0 ~ 250 3
SPATH SPATH Specifi es digipeater callsigns to be added when the UISSID
parameter in a received packet is 9 or 13. Call1, ... call7
STREAMCA STREAMC When ON and multiple connections take place, receiving a
packet causes the TNC to display the callsign. ON/ OFF ON
STREAMDB STREAMD When ON, causes the TNC to display a stream switch
character included in a received packet. ON/ OFF OFF
STREAMSW STR Specifi es a character to be used for switching streams. 0 ~ $7F $01
TOUT TOUT
Specifi es the time-out time of the TNC mailbox. When no
packet is received within the specifi ed time, a disconnect
takes place. The unit of the parameter is 10 seconds.
0 ~ 250 30
TRACE TRAC When ON, causes the TNC to display all received packets in
their entirety. ON/ OFF OFF
TRANS T
Causes the TNC to exit Command mode and enter
Transparent mode. To restore Command mode, press and
hold [Ctrl], then press [C] three times.
−−
TRFLOW TRF When ON, causes the TNC to respond to software fl ow
control from the computer in Transparent mode. ON/ OFF OFF
TRIES TRI Specifi es the number of transmission retries programmed in
the retry counter. 0 ~ 15 0
TXDELAY TX Specifi es the time delay between PTT ON and start of
transmission. The unit of the parameter is 10 milliseconds. 0 ~ 120 50
TXFLOW TXF When ON, allows the TNC to send a software fl ow control
(XON and XOFF) to the computer in Transparent mode. ON/ OFF OFF
UICHECK UIC
Does not forward the same UI packet as one received
within the time specifi ed by this command. The unit of the
parameter is 1 second.
0 ~ 250 28
UIDIGI UI
When receiving a UI packet which includes the parameter
specifi ed by this command, replaces the parameter with the
MYCALL parameter and forwards the packet.
OFF/
ON Call1, ... call14 OFF
UIDWAIT UIDW When ON and digipeating, causes the TNC to use the
DWAIT and PPERSIST settings. ON/ OFF OFF
UIFLOOD UIF
Specifi es how received UI packets, which include WIDEN-N
or TRACEN-N parameters, are processed. Enter WIDE or
TRACE before ID, NOID, or FIRST; ex. WIDE,FIRST. With
ID selected, deletes the relayed digipeaters and adds the
MYCALL parameter. With NOID, merely decrements N-N;
ex. 4-3 to 4-2. With FIRST, adds the MYCALL parameter
only when serving as the fi rst digipeater.
ID/ NOID/ FIRST ID
UISSID UIS When ON, causes the TNC to process received UI packets