GPS – 3
TRACK LOG
All movement is saved in the GPS Logger (Internal GPS only).
Saved information includes latitude, longitude, altitude, travel
direction, speed, time, and date. The log can retain up to 5000
points of data.
Press [LOG] to turn the Track Log function On or Off.
When turning the Track Log function On, “LOG START” appears
for approximately 5 seconds, followed by the “ ” icon.
• When turning the Track Log function Off, “LOG STOP” appears on
the display for approximately 5 seconds.
• With the Track Log function On, even if the power source is turned
Off during a Log acquisition, the log is backed up so that when the
power is turned back on, the log acquisition resumes.
• You can verify the Log activity ratio in the GPS pinpointing screen.
Note:
◆ When the Track Log is turned On while the GPS is Off, the GPS will also
turn On.
◆ When the GPS is not pinpointing, data is not saved to the log.
◆ You can read the Track Log using the MCP-6A.
◆ If the Track Log overwriting confi guration is turned Off (see below), “LOG
FULL” appears when the log memory is full.
◆ When the APRS is On, Log operation will begin only when the APRS menu
COM terminal input is Off.
■ Track Log All Clear
1 Press [ALLCLR].
• “CLEAR ALL?” appears. Press the Tuning Control to clear all
Track Logs.
■ Overwriting the Track Log
When the Track Log becomes full, new data will begin
overwriting the oldest Track Log data.
1 Enter Menu mode and access Menu 502.
2 Select “ON” or “OFF”.
• Selecting “ON” will allow old data to be overwritten with new
data.
LOG SETUP
Enter Menu mode and access Menu 503.
■ Record Method <RECORD METHOD>
You can set the conditions for saving Track information as
GPS Logger.
You can change the settings for travel speed, etc.
Select “TIME”, “DISTANCE”, or “BEACON” for the Record
Method.
■ Interval Time <INTERVAL>
Select an Interval time from 2 ~ 1800 seconds (in steps of 1
second).
• The Interval setting is available only if the Record Method has
been set to “TIME”.
■ Distance <DISTANCE>
Select a Distance from 0.01 ~ 9.99 (in steps of 0.01).
• The Distance setting is available only if the Record Method has
been set to “DISTANCE”.
• The units used for Distance can be set to miles (mi), kilometers
(km), or nautical miles (nm).
Interval and Log Total Time:
Point
Qty
Interval time (seconds)
2 5 10 15 30 1800
5000
166.7 416.7 833.3 1250 2500 150000
(min)
2.8 6.9 13.9 20.8 41.7 2500
(hour)
Interval and Total Distance:
Point
Qty
Interval distance (km)
0.01 0.10 2.00 4.00 6.00 8.00 9.99
5000 50 500 10000 20000 30000 40000 49950
(km)