Error Codes

Table 3

PROBLEM

 

CAUSE / SOLUTION

 

 

• Error 1

• Acceleration is too quick in an acceleration or reached speed phase.

 

 

 

• Possible causes: Motor drive defective or user pushing on the running belt for too long.

 

 

 

• Error 2

Running belt not following the speed required in the reached speed phase.

 

• Possible causes: Deck too sticky. Walk on deck for 15 minutes at 4 mph.

 

Motor drive board can be defective.

 

• Check speed sensor or optical disk.

 

 

 

• Error 11

Acceleration is too fast during acceleration phase.

 

• Possible cause: Defective drive board.

 

 

• Error 12

• Acceleration is too slow during acceleration phase.

• Possible causes: Deck too sticky.

 

 

• Walk on deck for 15 minutes at 4 mph.

 

Speed sensor problem.

 

 

 

• Error 21

In a deceleration phase, the speed slows too fast.

 

• Possible cause: Drive board defective.

 

 

 

• Error 22

In a deceleration mode, the speed slows down too slowly.

 

• Possible cause: Drive board defective, speed sensor problem.

 

 

 

• Error 23

There is an abnormal acceleration during deceleration.

 

• Motor drive board is defective.

 

• Acceleration is too quick under 2 mph.

 

 

 

• Error 31

Possible causes: Motor drive defective or user pushing on the running belt for too long.

 

• Elevation motor values from potentiometer are out of range.

 

• Possible causes: Elevation motor is defective or uncalibrated.

 

• Perform an elevation calibration in the diagnostics menu.

 

• Motor drive board can be defective.

 

 

 

• Elevation

Elevation Motor not functionnal.

Motor

Elevation Motor not connected.

Error

 

 

 

 

 

Thank You for Purchasing a Bodyguard® T240 – T260

Bodyguard® Fitness is dedicated to designing and manufacturing the finest fitness equipment available today.

This manual outlines information on warranty, assembly, operation of the unit, safety and basic maintenance checks for the Bodyguard® T240 – T260 treadmills.

When you require service for your T240 – T260, always present the unit product model, serial number and date of purchase to the Bodyguard® Dealer. The product model and serial numbers are located at the front of the machine. Now is a good time to write the product model and serial numbers and related information in the space provided.