Error Codes
Table 3
PROBLEM |
| CAUSE / SOLUTION | |
|
| ||
• Error 1 | • Acceleration is too quick in an acceleration or reached speed phase. | ||
|
| ||
| • Possible causes: Motor drive defective or user pushing on the running belt for too long. | ||
|
|
| |
• Error 2 | • | Running belt not following the speed required in the reached speed phase. | |
| • Possible causes: Deck too sticky. Walk on deck for 15 minutes at 4 mph. | ||
| • | Motor drive board can be defective. | |
| • Check speed sensor or optical disk. | ||
|
|
| |
• Error 11 | • | Acceleration is too fast during acceleration phase. | |
| • Possible cause: Defective drive board. | ||
|
| ||
• Error 12 | • Acceleration is too slow during acceleration phase. | ||
• Possible causes: Deck too sticky. | |||
| |||
| • Walk on deck for 15 minutes at 4 mph. | ||
| • | Speed sensor problem. | |
|
|
| |
• Error 21 | • | In a deceleration phase, the speed slows too fast. | |
| • Possible cause: Drive board defective. | ||
|
|
| |
• Error 22 | • | In a deceleration mode, the speed slows down too slowly. | |
| • Possible cause: Drive board defective, speed sensor problem. | ||
|
|
| |
• Error 23 | • | There is an abnormal acceleration during deceleration. | |
| • Motor drive board is defective. | ||
| • Acceleration is too quick under 2 mph. | ||
|
|
| |
• Error 31 | • | Possible causes: Motor drive defective or user pushing on the running belt for too long. | |
| • Elevation motor values from potentiometer are out of range. | ||
| • Possible causes: Elevation motor is defective or uncalibrated. | ||
| • Perform an elevation calibration in the diagnostics menu. | ||
| • Motor drive board can be defective. | ||
|
|
| |
• Elevation | • | Elevation Motor not functionnal. | |
Motor | • | Elevation Motor not connected. | |
Error |
|
| |
|
|
|
Thank You for Purchasing a Bodyguard® T240 – T260
Bodyguard® Fitness is dedicated to designing and manufacturing the finest fitness equipment available today.
This manual outlines information on warranty, assembly, operation of the unit, safety and basic maintenance checks for the Bodyguard® T240 – T260 treadmills.
When you require service for your T240 – T260, always present the unit product model, serial number and date of purchase to the Bodyguard® Dealer. The product model and serial numbers are located at the front of the machine. Now is a good time to write the product model and serial numbers and related information in the space provided.
30