6

Hardware Installation

Power Switch

The AC Power switch turns the unit ON or OFF. If the PWR LED does not light up once the unit has been turned on, try the procedures below (in the following order):

1.Try a different AC power outlet.

2.Check the external fuse located at the back of unit (below the AC power connector). If the fuse is blown, replace it with the spare fuse provided with the unit. (See Fuse Compartment display in Figure 3-3)

3.The power supply may be defective. Return the unit for replacement.

WARNING: For safety reasons, DO NOT attempt to open and service the unit. There are no user-serviceable components inside.

AC Power Connector

The Fast EtheRx dual-speed hubs use 100-240VAC internal power supplies. Connect the AC power cord from the back of the unit to an AC electrical outlet.

Fuse

The Fast EtheRx dual-speed hub comes equipped with one external fuse and one spare fuse. Both fuses are in a fuse holder located just below the AC power connector on the back of the unit. Both fuses are rated 250V/2A max.

Fig. 3-3 Fuses

Fan Unit(s)

The Fast EtheRx dual-speed hubs use independent cooling fans for optimum air- ow to safeguard the unit from unnecessary heat exposure.

Kingston Technology Company

KND2415TX User’s Guide - Rev. A00

Page 11
Image 11
Kingston Technology KND2415TX manual Power Switch, AC Power Connector, Fuse, Fan Units