12

Appendix B Cabling Guidelines

UTP Cable Wiring Standards

There are two governmental agencies: the Electronic Industry Association (EIA) and the Telecommunications Industry Association (TIA), which set the standard for all cable wiring requirements for commercial buildings.

With the advent of 100Mb/s networking products, it is best to use higher quality CAT 5 cables like Belden or Helix as well as CAT 5-compliant patch panels, patch cables, and connectors while following the EIA/TIA wiring standards. 100 Ω UTP CAT 5 type cables use 4-pair UTP wiring.

Refer to the illustrations below for 4-pair wiring using either T568A (Fig. B-1) or T568B (Fig. B-2) wiring standards. Both T568A and T568B wiring is compatible with 10BASE-T and 100BASE-TX and require no special configurations, but for premise wiring, stick to one wiring standard. Mixing T568A and T568B wiring schemes may cause or lead to potential problems.

Pair 2

Pair 3

Pair 3 Pair 1 Pair 4

Pair 2 Pair 1 Pair 4

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

T568A

T568B

Fig. B-1 4-Pair T568A Wiring

Fig. B-2 4-Pair T568B Wiring

T568A

Pairs

Strand

Solid

Pin 1

Pair 3

Blue

White/Green

 

 

 

 

Pin 2

Pair 3

Orange

Green/White

 

 

 

 

Pin 3

Pair 2

Black

White/Orange

 

 

 

 

Pin 4

Pair 1

Red

Blue/White

 

 

 

 

Pin 5

Pair 1

Green

White/Blue

 

 

 

 

Pin 6

Pair 2

Yellow

Orange/White

 

 

 

 

Pin 7

Pair 4

Brown

White/Brown

 

 

 

 

Pin 8

Pair 4

White

Brown/White

 

 

 

 

Table. B-4 4-Pair T568A Wiring

T568B

Pairs

Strand

Solid

Pin 1

Pair 2

Black

White/Orange

 

 

 

 

Pin 2

Pair 2

Yellow

Orange/White

 

 

 

 

Pin 3

Pair 3

Blue

White/Green

 

 

 

 

Pin 4

Pair 1

Red

Blue/White

 

 

 

 

Pin 5

Pair 1

Green

White/Blue

 

 

 

 

Pin 6

Pair 3

Orange

Green/White

 

 

 

 

Pin 7

Pair 4

Brown

White/Brown

 

 

 

 

Pin 8

Pair 4

White

Brown/White

 

 

 

 

Table B-5 4-Pair T568B Wiring

Kingston Technology Company

KNS800/WG User’s Guide – Rev.B01

Page 16
Image 16
Kingston Technology KNS800/WG, KNS500/WG manual UTP Cable Wiring Standards, T568A T568B