BLACK S2

TH

 

TP

WHITE T2

 

TH TP

RED T1

 

THERMOPILE

GAS VALVE

BLACK S1

Figure 30. Standing Pilot Ignition Wiring Diagram

OPTIONAL REMOTE

OPTIONAL WALL SWITCH

Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION.

For Standing Pilot Ignition Wiring

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to operate.

!WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE AP- PLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED.

Optional Accessories

Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.

Remote Wall Switch

Position the remote wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC ! TO THE REMOTE WALL SWITCH OR THE

CONTROL VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPERAND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

BLK

BLK

BLK

VARIABLE SPEED CONTROL

BLK

JUNCTION BOX

BLK

BLK

BLK

WHT WHT

BLK

GROUND

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105OC RATED WIRE.

BLOWER RECEPTACLE

TEMPERATURE

SENSOR SWITCH

BLOWER

GRN

JUNCTION BOX

BLK

WHT

110-120 VAC

FAN

Figure 31. Fan Wiring Diagram