STRAIGHT UP

VERTICAL VENTING

 

V (FT.)

40' MAX. (12.4 M)

Figure 6.

Straight Up Vertical Venting

NOTE: On vertical venting configurations where the vertical component is over 10 feet, you may want to install the vertical baffle (VERT-BAF) (see Figure 7).

 

5” EXHAUST

 

PIPE

 

VERTICAL

 

BAFFLE

 

CENTER VERTICAL

 

BAFFLE ON 5”

 

EXHAUST PIPE

Figure 7.

Vertical Baffle

NOTE: Center the vertical baffle over the 5” exhaust pipe. Fasten in place with self tapping screws.

HORIZONTALVENTING

Kit No. H Max. Run

DVK-01D

DVK-01TRD 24" (610 mm)

H

90-DEGREE ELBOWS

45-DEGREE

ELBOW

NOTE: BE-41 model is tested and approved to use 45° elbows in corner installations. However, 90° elbows will result in better per- formance.

Figure 8. Corner Installation