KitchenAid 2005 Make Electrical Connection, Install Filters, Check Operation, B C D E A F

Models: 2005

1 24
Download 24 pages 38.43 Kb
Page 8
Image 8
Make Electrical Connection

Make Electrical Connection

Electrical Shock HazardWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power at the circuit breaker of fused circuit box.

2.Connect the white wire of the power supply cable with the white lead in the range hood using a twist-on connector.

3.Connect the black wire of the power supply cable with the black lead in the range hood using a twist-on connector.

Replace all parts and panels before operating.WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death or electrical shock.

4.Connect the green power supply ground wire to the unused, green ground screw.

B Failure to do so can result in death or electrical shock. C

D

Connect ground wire to green ground screw in terminal box.E

A B  C

F

A. Green ground screw

B. Hood wiring

C. White wires

D.Twist-on connectors E. Black wires

F. Power supply cable

5.Tighten strain relief screws.

6.Replace the terminal box cover.

Install Filters

1.For recirculating installations only, install the charcoal filters included in Recirculation Kit Part Number 4396565. Place the charcoal filter against the blower cover and rotate to the right (clockwise) to attach to cover. Repeat with other charcoal filter.

A

A.Filter

2.Replace metal filter. Turn knob on metal filter to the right (clockwise) to attached to range hood.

Check Operation

1.Check operation of the range hood by turning on the power.

2.The range hood controls are located on the right-hand underside of the range hood.

A

B

A.Controls

B.Filters

3.Move the light switch to “1” position. The light should turn on.

4.Move blower switch to “1” position. The blower should operate.

5.Move the blower speed switch to “1” position for low speed, “2” position for medium speed or “3” position for high speed.

6.Move blower and light switches to “0” position to turn blower and light off.

7.If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power supply and check that the wiring is correct.

NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.