If blower box is removed from vent base, check that wiring cable is properly secured in plastic clips.

Determine which direction (down or rear) ductwork will need to run from blower duct when installed in cabinet.

Down venting:

Downdraft vent is shipped with blower in down venting position so no modification is required. Go to Step 7.

Left or right venting:

a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box.

b. Rotate blower box 90” to left or right so that vent blower is repositioned in the direction needed.

c. Reattach blower box to downdraft vent base with 4 hex nuts.

Rear venting:

a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box.

b. Note how wiring cable is installed under plastic clips inside vent base. Then carefully remove wiring cable from plastic clips. Disconnect blower wiring cable.

c. Remove 6 Phillips-head screws attaching blower to blower box. Remove blower.

bracket for

d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws.

e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6 Phillips-head screws.

NOTE: Square metal frame attached to mouth of blower must be installed for proper operation.

f. Attach metal cover from parts bag over down-venting knockout in blower box. Remove rear knockout cover on back of vent base.

g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base. Reattach blower box to downdraft vent base with 4 hex nuts.

17.1

II

Attach backdraft damper over blower box knockout with 2 Phillips-head screws.

1 8.1 Remove the 2 Phillips-head

r1 screws attaching appliance wiring box cover. Determine which direction (rear or down) electrical connection will need to run from appliance wiring box. Knock out rear or lower wiring opening in wiring box.

Interior-mounted blower

Injury Hazard

Use two or more people to move and install downdraft vent.

Failure to follow this instruction can result in back or other injury.

lg.1Insert downdraft vent into countertop cutout. Two people are

recommended to support the weight bf the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to cabinet floor with screws. Snap end caps over top of mounting brackets,

When attaching undercounter bracket to underside of countertop:

Do Not drill into countertop surface.

Check that mounting screws are proper length and will not go through countertop surface when tightened.

on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop.

Numbers correspond to steps.

hnr

knockouts

Disconnect power supply. Thread the power supply cable

through the knockout opening in the wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) grounding wire to eyelet with green grounding screw. Reattach the wiring box cover.

microswitches behind filters. ON/OFF

/\, button

Turn power supply on. Push the button on the top of the

downdraft vent. Retractable section of downdraft vent will rise and blower will start. Turn the control knob on side of vent to check the operation and speed of blower.

If blower does not operate:

l Check that filters are pressed in as far as they will go.

l Check that circuit breaker is not tripped or house fuse blown.

l Disconnect power source and check that wire connections have been made correctly

Connect ductwork to blower. Position ductwork to avoid wall

studs and floor joists. Complete all ductwork. Use duct tape to seal all joints. Ductwork must end with a wall or roof cap.

Install cook-top according to manufacturer’s instructions.

Check that rear edge of cook-top overlaps edge of downdraft vent by 3/8”.

To get the most efficient use of your new retractable downdraft vent, read Use & Care Information section on Panel G.

Keep Installation Instructions and Use & Care Information close

for easy reference.

Panel D

Page 5
Image 5
KitchenAid 30 and 36 Retractable Downdraft Vent Systems installation instructions Interior-mounted blower, Panel D

30" and 36" Retractable Downdraft Vent Systems specifications

KitchenAid has long been recognized for its commitment to quality and innovation in kitchen appliances, and its 30" and 36" Retractable Downdraft Vent Systems are prime examples of this dedication. Designed to enhance kitchen functionality while maintaining a sleek aesthetic, these downdraft vent systems effectively capture smoke, steam, and odors from cooking without obstructing kitchen sightlines.

One of the main features of KitchenAid’s downdraft vent systems is their powerful ventilation capability. With a robust airflow performance, these vents can efficiently remove unwanted cooking byproducts, improving air quality in the kitchen and making cooking a more enjoyable experience. The retractable design allows the vent to only be present when needed, maintaining a clean visual appeal when not in use. This seamless integration into the countertop is especially beneficial in open-concept kitchens where maintaining an uncluttered look is essential.

Both the 30" and 36" models are equipped with an easy-to-use control interface, offering multiple fan speeds to cater to different cooking situations. The low speed setting is ideal for simmering, while higher speeds can be activated for frying or grilling, capturing even the most challenging odors and smoke. The noise level is designed to be minimal, ensuring that conversations and kitchen activities can continue without disruption.

Another stand-out feature is the filter system. The downdraft vents utilize dishwasher-safe grease filters, making maintenance convenient and straightforward. This feature not only promotes effective grease capture but also ensures that the system remains hygienic over time.

Moreover, KitchenAid incorporates advanced technologies in its downdraft vent systems, such as the powerful motor that offers a reliable performance even in high-demand cooking scenarios. The models also come with adjustable height options, allowing users to customize the vent's exposure based on their cooking needs.

In terms of design, both the 30" and 36" systems are available in various finishes to match different kitchen styles, from sleek stainless steel to more contemporary options. This versatility allows homeowners to choose a model that complements their kitchen aesthetics while benefiting from its functional features.

In conclusion, KitchenAid's 30" and 36" Retractable Downdraft Vent Systems exemplify the brand's focus on blending form and function. With their powerful ventilation capabilities, user-friendly controls, and efficient design, these downdraft systems are perfect for discerning cooks who seek both performance and style in their kitchens.