13
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
grill to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the grill to the rigid gas supply
line. A ⁵⁄₈" diameter line is recommended. Using a wrench
to tighten, connect the gas supply to the grill.
Use pipe-joint compound on all non-flared male threads.
Do not kink or damage the flexible connector when
moving the grill.
Pipe-joint compounds suitable for use with Natural gas
must be used. Do not use TEFLON®† tape.
2. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
4. Go to “Check and Adjust the Burners” section.

Plug in Grill

1. Plug into a grounded 3-prong outlet.
Style 2 - Built-In Outdoor Grill Installation
Unpack grill. Remove all packaging materials and remove grill
from carton.
Move grill close to desired outdoor location.
Open the hood.

Remove Packaging Material Inside the Grill

1. Cut the tiedowns holding the grates together.
2. Remove rotisserie skewer (on some models), warming shelf
and grill grates from inside the grill and remove packaging
material.
3. Remove foam block and wrap from inside the grill.
4. Replace the grill grates.
A.Grill gas pipe
B.New ANSI Z21.54 certified gray hose
C.Rear of grill
D.To Natural gas supply
A.Closed valve
B.Open valve
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A
B
C
D
A
B
A.Foam block
B.Foam wrap
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.

Failure to follow these instructions can result in death,

fire, or electrical shock.
WARNING

Excessive Weight Hazard

Use two or more people to move and install grill.

WARNING

Failure to do so can result in back or other injury.

A
B