Location Requirements

The refrigerator can be recessed in an opening between cabinets

A grounded 3 prong electrical outlet should be placed within

or installed at the end of a cabinet run using a side panel to

4" (10.2 cm) of the right side cabinets or end panel. See

enclose the refrigerator.

“Electrical Requirements” for additional information.

 

The water shutoff should be located in the base cabinet on

WARNING

either side of the refrigerator or some other easily accessible

 

area. If the water shutoff valve is not in the cabinets, the

 

plumbing for the water line can come through the floor or the

 

back wall. See “Water Supply Requirements” for more

 

information.

Explosion Hazard

 

 

Keep flammable materials and vapors, such as

80" - 90"

 

gasoline, away from refrigerator.

 

(203-229 cm)

 

 

4"

Failure to do so can result in death, explosion, or fire.

 

 

(10.2 cm)

 

 

IMPORTANT:

 

 

Observe all governing codes and ordinances.

 

 

It is recommended that you do not install the refrigerator

 

 

near an oven, radiator, or other heat source.

83¹⁄₄" (211.5 cm) min.

 

Do not install in a location where the temperature will fall

84³⁄₄" (215 cm) max.

 

to bottom of solid soffit

 

below 55°F (13°C).

 

 

 

Floor must support the refrigerator weight, more than

 

 

600 lbs (272 kg), door panels and contents of the

 

 

refrigerator.

 

77"

Ceiling height must allow for side tipping radius. See

 

 

(196 cm)

“Tipping Radius.”

 

 

Location should permit doors to open fully. See “Door

 

 

Swing Dimensions.”

A

 

Location must permit top grille removal. See “Opening

Width

 

(see chart following)

 

Dimensions.”

 

 

Opening Dimensions

 

6"

 

 

(15.2 cm)

The solid soffit must be within 1" (2.5 cm) maximum above

 

 

the refrigerator. If the solid soffit is higher than 1" (2.5 cm) or

 

3"

one is not available, then the refrigerator must be braced to

 

(7.6 cm)

prevent tipping during use.

 

 

If the anti-tip boards are needed, they must be attached to

11"

 

the rear wall studs 80" to 90" (203 cm to 229 cm) above the

 

floor. See “Install Anti-Tip Boards” for more information.

(28 cm)

 

 

 

NOTE: A clearance of ¹⁄₂" (1.3 cm) must be maintained above

6"

6"

the top grille in order for the top grille to be removed.

(15.2 cm)

(15.2 cm)

 

23¹⁄₂"

 

 

(60 cm) min.

 

¹⁄₂"

(1.3 cm)

Model Width A (as shown above)

3635¹⁄₂" (90.2 cm)

4241¹⁄₂" (105.4 cm)

4847¹⁄₂" (120.7 cm)

16