Non-Vented (Recirculating) Installation
1.Attach the air deflector to the upper horizontal support using 4 mounting screws.
B
A
B
A.Deflector
B.Mounting screws
2.Measure the length of 6" (15.2 cm) duct needed to connect the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm) minimum.
3.Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove the deflector from the chimney support bracket and replace after vent section is in place.
4.Seal all connections with vent clamps.
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Remove terminal box cover.
3.Remove the knockout in the terminal box and install a UL listed or CSA approved ¹⁄₂" strain relief.
A B
C
4.Run home power supply cable through strain relief, into terminal box.
A B
C
D
EF
A.Home power supply cable
B.UL listed or CSA approved strain relief
C.Black wires
D.UL listed wire connectors
E.White wires
F. Green (or bare) and
5.Use UL listed wire connectors and connect black wires (C) together.
6.Use UL listed wire connectors and connect white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
7.Connect green (or bare) ground wire from home power supply to
8.Tighten strain relief screw.
9.Install terminal box cover.
10.Check that all light bulbs are secure in their sockets.
11.Reconnect power.
A.Knockout
B.Terminal box
C.Terminal box cover
8