8DN9610 AES50 Repeater
DN9610 AES50 Repeater
1. Introduction
Welcome!
Thank you for purchasing a Klark Teknik DN9610 AES50 Repeater.
The DN9610 is a premium quality, dual channel Klark Teknik AES50 repeater box. A single DN9610 extends any AES50 connection by up to a distance of 100 metres, but for greater distances multiple DN9610 devices can be connected together in series
This DN9610 is particularly designed for sound reinforcement as an extension to existing AES50 network connections. A pair of AES50 ports is provided so that current AES50 devices that use redundant ‘X’ and ‘Y’ networks can be catered for within a single box.
The DN9610 has two inputs and outputs that provide
Note: Although AES50 is a
The DN9610 was conceived by Klark Teknik to off er audio professionals high performance audio equipment, designed to provide
So, to obtain the best results with a minimum of eff ort, please read this operator manual and, fi nally, enjoy your Klark Teknik DN9610 AES50 Repeater!
2. Key features
The DN9610 has the following key features:
•Dual AES50 repeater
•2 x AES50 Ethercon 'inputs' and 'outputs'
•AES50 activity LED per input and output
•2 x +9V to +18V DC power supply inputs (second DC power supply option for redundancy)
•External DC power supply unit with lockable connector
•Power LED
•Rugged construction designed for live use
•Tough, but easily replaceable silicone rubber sleeve with interlocking roundels (top and bottom) for easy stacking
3. Getting Started
3.1 Unpacking
Carefully unpack your DN9610 equipment package. Then inspect the DN9610 unit carefully for any signs of damage that may have occurred during transit and notify the courier immediately if you discover any.
Check the contents of your DN9610 equipment package. If there are any parts missing, incorrect or faulty, please contact your local distributor or Klark Teknik at the address at the front of this manual.
Please retain the original packing in case you should need to return the equipment to the manufacturer or supplier, or transport or ship the unit later.
3.2 Installation
DC inlets are provided on the rear panel. The correct mains power adaptor is supplied with the unit complete with a selection of country variant plug attachments to suit your local mains power outlet socket requirements.
3.3 Connecting up
When connecting up, note the following:
•AES50 cables can be up to 100 m long and must be Cat 5e or Cat 6.
•Always connect DN9610 inputs to clock master and DN9610 outputs to clock slave.
•Always connect AES50 cables to like numbered input and output ports. For example, if you are connecting to input port AES50 IN 1, connect its output to AES50 OUT 1.
•When
•With power on, when you connect an AES50 cable to the unit (input or output) its local green 'activity' LED will illuminate. When the connection is active the LED will fl ash.
klarkteknik.com