INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to Table 1. (All calculation in inches.)
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter
Top (Standard: 36”)
C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”)
D = Height of Hood
E = Height of the Hood
Installation [A – (B + C)]
F = Height of Duct Cover [E – D]
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR.
Preparations before Installation
NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.
-Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
-A straight, short venting run will allow the hood to perform more efficiently.
-Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.
-Use duct tape to seal the joints between pipe sections.
4