Mounting
Screws
Figure 5
Ductwork Installation
5.Use 6 round aluminum or steel pipe to connect the plastic exhaust on the hood ductwork above. Use duct tape to make all joints secure and air tight. Refer
Figure 6
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
6.Connect three wires (black, white and green) to house wires and cap with wire connectors.
7.Connect according to color: black to black, white to white, and green to gree
8.Test the operation of the hood before moving on to next step. Make sure power supplied to the hood.
Duct Cover Installation
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCURS.
6