Error Codes (continued)

 

 

 

Code

Explanation

Action Needed

 

 

 

55

Elevator tray 2 malfunctioned.

Open paper cassette #2. Check paper position,

 

 

and close paper cassette. If the problem persists,

 

 

call for service.

 

 

 

56

Elevator tray 3 malfunctioned.

Open paper cassette #3. Check paper position,

 

 

and close paper cassette. If the problem persists,

 

 

call for service.

 

 

 

57

Elevator tray 4 malfunctioned.

Open paper cassette #4. Check paper position,

 

 

and close paper cassette. If the problem persists,

 

 

call for service.

 

 

 

58

The ozone fan malfunctioned.

Turn the printer off and then on again. If the

 

 

problem persists, call for service.

 

 

 

59

The power supply fan malfunctioned.

Turn the printer off and then on again. If the

 

 

problem persists, call for service.

 

 

 

80

There is a problem with the sorter.

Turn the printer off and then on again. If the

 

 

problem persists, call for service.

 

 

 

Preventive Maintenance Codes

Code

Explanation

Action Needed

 

 

 

P0

EP unit needs replacement.

Install a new EP unit*, or call for service.

 

 

 

P2

The toner collection bottle is full.

Replace with a new collection bottle. See

 

 

page 2-11.

 

 

 

Caution Codes

Code

Explanation

Action Needed

 

 

 

C0

The toner collection bottle is near full. The

Replace the toner collection bottle with a new

 

printer will shut down approximately 500

one. See page 2-11.

 

prints after this error is posted.

 

 

 

 

C1

The toner bottle is almost empty.

Replace the toner bottle with a new one.

 

 

See page 2-9.

 

 

 

C2

The fuser web is almost used up. The printer

Replace with a new fuser unit* or call for service.

 

will shut down approximately 500 prints

 

 

after this error is posted.

 

 

 

 

*These maintenance procedures are to be performed by Kodak authorized and fully trained persons only. These errors (for the EP unit and fuser unit) normally appear every 150,000 prints. At this time, an Image Quality Kit needs to be installed. This kit includes: a new EP unit, a fuser unit, a transfer/separator corona, and feed rollers. Customers with a Shared Maintenance Agreement will install the Image Quality Kit. Other customers should call Service immediately.

A-62032 November 1996

C-3

Page 26
Image 26
Kodak 7 manual Preventive Maintenance Codes Explanation Action Needed