Calibrating the Printer

24.Look at the test print and determine which cluster appears the most neutral (has the least amount of color).

25.Enter the number of the most neutral cluster in the Cluster Number box (range 201-249).

26.Click Done.

The printer calibration begins. When calibration is complete, the following dialog box appears.

27.Click Quit to close the Calibration Utility. Your printer is now calibrated.

NOTE: The neutral cluster should be in the center of the test print (#225) if the printer is properly calibrated.

Uninstalling the Calibration Software

You can remove the calibration software from your computer in two ways:

Select Start > Programs > KODAK Calibration Utility 1.1.2 > Uninstall KODAK Calibration Utility 1.1.2 and follow the directions to uninstall the software.

Select Start > Settings > Control Panel > Add/Remove Programs > KODAK Calibration Utility and follow the directions to remove the software.