Scanner Time
•Actual (GMT): displays the Greenwich Mean Time of the scanner.
•Corresponding local time: displays the scanner’s Greenwich Mean Time in the PC’s local time zone.
Refresh: displays the scanner time.
Calibrate — displays the Calibration window allowing you to perform an Image or UDDS calibration.
•Image calibration: optimizes your scanner to achieve the best image quality and feeding performance. Frequent calibration is not necessary or recommended.
•UDDS calibration: ensures that the ultrasonics system that detects
Use the calibration target provided with your scanner. Be sure to use a good, clean calibration target.
1. Click Calibrate. The Calibration dialog box will be displayed.
2.Select Image or UDDS from the Type
•If you select Image, use the calibration target provided with your scanner. Be sure to use a good, clean calibration target. Place the calibration target in the input elevator face up and click OK.
IMPORTANT:If the White Background Accessory is installed, it must be replaced with the black background stirps, and the scanner must be restarted prior to calibration.
•If you select UDDS, place a 20 lb. or 75 g.m2 bond sheet of paper in the input elevator. Do not use the calibration target and click OK.
|