Kohler CFI230J manual Troubleshooting, Malfunction, Cause, Remedy

Models: CFI230J

1 14
Download 14 pages 41.65 Kb
Page 13
Image 13
TROUBLESHOOTING

TROUBLESHOOTING

The information below gives details on what you can do as a user should you encounter difficulties whilst operating the shower.

If there is a problem with the shower control some of the push buttons will flash very fast.

Malfunction

Cause

Remedy

 

 

 

Push buttons are

Water supply isolated

Check water supply

flashing on the shower

 

 

control and / or the

Damaged or broken cable

Check cable connections

shower will not operate

connection

 

 

Electrical supply isolated

Check electrical supply

 

or fuse blown

 

 

Digital Mixer Valve

Isolate product and turn

 

breakdown

back on after 30 seconds

 

 

If the problem still

 

 

persists note the

 

 

sequence of the flashing

 

 

push buttons and

 

 

contact Customer

 

 

Services

 

 

 

No flow or low flow rate

Spray plate assembly

Refer to Cleaning

from the Shower Fittings

blocked

 

 

Hose blocked or twisted

Clear blockage or

 

 

release twist in hose

 

Digital Mixer Valve malfunction

Contact Customer Services

 

 

 

Drip from spray plate

A small amount of water

This is quite normal.

assembly on handset

may be retained in the

Changing the angle of

 

shower fitting after the

the shower fitting may

 

shower control has been

vary the draining time

 

turned off. This may drain

 

 

over a few minutes

 

 

Digital Mixer Valve

Solenoid fault. May

 

malfunction

require cleaning or

 

 

replacement. Contact

 

 

Customer Services

 

 

 

Incorrect shower

Maximum temperature

Refer to Commissioning,

temperature

incorrectly set

Maximum temperature

 

 

setting

 

Digital Mixer Valve incorrectly

Make sure that the hot

 

fitted

and cold water supplies

 

 

are connected correctly

 

 

 

Malfunction A

4

3

2 1

B

Handset Adjustment

To adjust the height of the handset press the release button ‘A’ and slide the clamp bracket assembly up or down to the desired position.

The handset can be moved both vertically and horizontally until the desired position is reached ‘B’. A friction mechanism in the clamp bracket will hold the handset in place.

Fixed Head Adjustment

Move the spray head to the required position. The spray head is adjustable in both the horizontal and vertical directions.

16 CFI230J

CFI230J 13

Page 13
Image 13
Kohler CFI230J manual Troubleshooting, Malfunction, Cause, Remedy