COMMISSIONING/SETTING
1.General
1.1.Turn on the water supply to the Digital Mixer.
1.2.Check for leaks over the complete system.
1.3.Turn on the electrical supply to the Digital Mixer.
For the Pumped Version with the Slide Rail System, pump priming can be helped by removing the handset and lowering the end of the hose into the shower tray.
2. Set the Maximum Temperature
Note! The maximum temperature of the unit can only be set when the unit has not been used for a period of 10 minutes or after switching the unit’s electrical supply OFF and ON.
2.1.Temperature Selection - Set the temperature control knob to the desired position, as per the table below.
Temperature Control | Temperature Selection °C |
Knob Position |
|
|
|
1 | Factory Set 45°C |
|
|
2 | 45°C |
|
|
3 | 36°C |
|
|
4 | 38°C |
|
|
5 | 40°C |
|
|
6 | 42°C |
|
|
7 | 45°C |
|
|
8 | 47°C |
|
|
9 | 48°C |
|
|
2.2. Enabling - Press and momentarily hold the Warm Up/Stop and High
3.Lock Mode
Note! Allows you to lock the unit during operation.
3.1.There are two Safety Lock Modes
Option 1 - Locks the mixer to your flow and temperature settings.
Option 2 - Locks the interface so no
Note! The Warm Up/Stop
14 CFI230J
Setting Option 1
Operate the shower and set the desired flow and temperature, then press and momentarily hold the Warm Up/Stop and Medium
The mixer is locked to your selected temperature and flow. Pressing any flow
Caution! If the temperature control knob is altered while the mixer is in standby mode or while
the shower is in operation, the water temperature settings will be changed to the new setting next time the shower is used.
Note! Selecting the Warm Up/Stop and Medium
Setting Otion 2
Note! This can only be set when the mixer has not been used for a period of 10 minutes. Switching the unit’s electrical supply OFF and ON cancels the lock mode.
Press and momentarily hold the Warm Up/Stop and Medium
Note! Selecting the Warm Up/Stop and Medium
4. Timeout
Note! Timeout allows you to run the shower for a set period of time before it automatically shuts off. This can only be set when the unit has not been used for a period of 30 minutes or after switching the unit‘s electrical supply OFF and ON.
4.1.Timeout Selection - Set the temperature control knob to the desired position, as per the table below.
Temperature Control | Timeout (Minutes) |
Knob Position |
|
|
|
1 | 30 |
|
|
2 | 30 |
|
|
3 | 3 |
|
|
4 | 4 |
|
|
5 | 5 |
|
|
6 | 6 |
|
|
7 | 7 |
|
|
8 | 8 |
|
|
9 | 9 |
|
|
4.2.Enabling - Press and momentarily hold the Warm Up/Stop and Low