Kohler K-12105-H, K-12106-H manual Pump Banding Strap CUT, Install Plumbing

Models: K-12106-H K-12105-H

1 16
Download 16 pages 8.71 Kb
Page 11
Image 11

B. PUMP BANDING STRAP CUT

NOTICE: This step is necessary to make your Kohler whirlpool operate more quietly.

1. Use tin snips to cut the two banding straps. These

banding straps secure the pump to the

whirlpool-mounted shipping bracket. When the

banding straps are cut, the pump base and pump

will drop about 1/2º until they rest on the subfloor. If

the pump drops more than 1/2º, be sure the proper

pitch is maintained (with shims under the motor) to

allow the pump to drain through the suction line

Pump

Suction Line

Shipping Bracket (leave attached to bath)

Banding Straps

Pump Base

when the whirlpool is drained.

2. If the subfloor is level, no adjustments to the pump

are necessary. Proceed to Step 3. If the subfloor is

not level, slide plywood shims between the pump

base and the subfloor, but only high enough to allow

water to drain out the suction line when the bath is

drained.

NOTE: Do not raise the pump higher than it was before you cut the banding straps. If the pump is raised too high, it may not prime properly.

3.To minimize bath noise and vibration, be sure the pump is not in direct contact with the shipping bracket after the banding straps are cut. The pump base contains rubber isolation feet to reduce pump noise and vibration.

Subfloor

Drainage

Suction Pipe

Shim if necessary, using 5º x 7º (minimum) plywood

Pump

Rubber

Isolation

Feet

C. INSTALL PLUMBING

CAUTION: Risk of damage to bath bottom and subfloor. Ensure a watertight seal on the bath drain connections.

1.When the bath is securely positioned, connect the drain to the trap.

NOTE: An access panel will simplify future mainte- nance.

2.Open hot and cold valves and check all supply connections for leaks.

3.Run water into the bath, and check the drain connections for leaks.

Connect Here