B. OPERATING SEQUENCE

Refer to the chart at right for the proper operating sequence.

1.Turn on the whirlpool jets. Adjust each jet for optimum air/water mixture.

2.A built-in timer automatically stops the motor after approximately 20 minutes of operation.

3.A built-in heater automatically maintains the water temperature while whirlpool bathing.

TO

METHOD

OBSERVE

Turn on whirlpool massage and the heater.

Decrease flow by

 

Up/

pressing key;

 

More

increase flow by

 

Down/

pressing key.

 

Less

To add air and

Reduce

Add Air

water to whirlpool

Air and

and

action, rotate

Water

Water

the trim ring

 

 

 

counterclockwise.

 

 

To reduce air and

 

 

water, rotate it

 

 

clockwise.

 

 

Shut off whirlpool.

 

 

Restart whirlpool after 20 minute cycle is complete.

14. TROUBLESHOOTING PROCEDURES

A. FLEXJET INSTALLATION

NOTE: The Flexjet O-ring must be correctly positioned, must be lubricated, and must be in good condition to permit easy rotation and proper operation.

1.Install the O-ring onto the first shoulder of the Flexjet. Lubricate the O-ring with silicone lubricant to prevent noisy operation of the Flexjet.

2.Insert the Flexjet into the housing, and lightly push and rotate the Flexjet until it snaps into position. Do not force the Flexjet.

NOTE: When installed correctly, the Flexjet should turn smoothly both clockwise and counterclockwise.

Flexjet Housing

Slide O-Ring

Flexjet

O-Ring (Must

Be Lubricated)