ROUGHINGIN AND INSTALLATION CONSIDERATIONS
Kohler low profile, onepiece toilets are perfect for remodel ing and new installations. Refer to the roughingin draw ings Figs. #4 - #9.
Always refer to your local codes and the installation in structions packed with the toilet.
KOHLER LOW PROFILE ONEPIECE TOILET FEATURES
Onepiece design offers contemporary styling.
Elongated bowl offers a large water area for efficient waste removal.
Nonoverflow design prevents the bowl from overflowing if the toilet becomes clogged.
Rialto, San Raphael, Cabernet, and Pillow Talk toilets flush with 3.5 gallons of water for greater economy.
TwistLock flush valves on new Rialto, San Raphael, Cabernet, and Pillow Talk toilets offer ease of replace ment with no tools.
Siphon vortex action provides excellent flush and quiet operation.
Large water area in bowl aids in effective waste removal.
STARTUP AND OPERATION FOR RIALTO, SAN RAPHAEL, CABERNET, AND PILLOW TALK TOILETS
For most satisfactory operation of this toilet, 25 to 90 psi working pressure is required at the fixture. A full 1/2" sup ply stop
1.Water Level Adjustment: Refer to Fig. #10. Turn on the water supply to the toilet and adjust the water level in the tank to the Water Line mark on flush valve. To raise the water level, turn the tank water level on float valve counterclockwise. To lower the water level, turn the screw clockwise.
2.Bowl Water Level Adjustment: Use the trip chain to lift the flush ball in the tank slightly, to allow water to trickle into the bowl until the water level in the bowl stops ris ing. This is the "seal height" and should be noted for subsequent adjustment. Flush the toilet and observe the water level in the bowl after refill. If the water level is
Tank Water Level
Screw
Timing Screw
Slotted screw on newer models
Seal Screw
Adjusting the Float Valve
Fig. #10
below seal height, turn the seal screw clockwise, reflush the toilet and recheck the water level. Continue adjustment until water stops entering the bowl just as the seal height is reached.
If water continues to flow (in bowl) after water level reaches seal height, turn seal screw counterclockwise and reflush toilet. Continue adjustment until water stops entering the bowl just as the seal height is reached.
3.High Water Pressure Timing: Note: If toilet is installed in an area with high water pressure (above 50 psi work ing pressure), the float valve should be timed. To time the float valve hold the float rod and flush the toilet. After the toilet has completed the flush, time the refill from re lease of rod to valve
For
For
- 3 -