•Use the supplied connecting cable only.
•Arrange for defective plugs, connection terminals or cable to be replaced at once by qualified techni- cians or our Customer Service Department.
•Get customer service to repair or replace connecting cables and/or devices that are not functioning properly or have been damaged.
•You may not open the casing or repair the device yourself. Should you do so, the safety of the device may be compromised and the warranty becomes void.
NEVER submerse the device in water.
Wipe it only with a slightly damp cloth.
Risk of fire!
•Do not use the device near hot surfaces.
•Do not locate the device in places exposed to direct sunlight, Otherwise, it may overheat and become irreparably damaged. Do not operate the device in a vehicle that is standing out in the sun.
•Do not leave the device unattended when in use.
•Do not cover the fan's ventilation slots when the device is switched on.
•Do not place any open sources of fire, like candles, on the device.
•Both connection cables can become heated when subjected to heavy loads.
•Due to high crossover resistances heating of the plug in connector can result when using the cables with a 12 V vehicle plug. Therefore when operating with high loads use the connection cable with the connection terminals.
Notice regarding disconnection from
•This device's on/off switch does not completely disconnect the device from the vehicle's power and/or the battery. When the vehicle plug is connected power is still supplied to the device. To completely disconnect the device from the vehicle power the 12 V vehicle plug must be re- moved from the vehicle socket or the connection terminals removed from the automobile battery.
Risk of personal injury!
•Do not operate the device if it has fallen or is damaged. Have the device checked and repaired if necessary by qualified technicians.
Technical data
DC Input
Voltage : | 12V |
|
|
|
|
|
|
| ||||||
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Maximum voltage: | 15,5 V |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
| ||||||
Maximum power |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
consumption: | 40 A | |||||||||||||
Underload alarm: | at 10,6 ± 0,3 V | |||||||||||||
Underload shutoff: | at 10 ± 0,3 V | |||||||||||||
Overload shutoff: | at 16 ± 0,5 V |
AC Output
Voltage : | ||
Output power: | 1,3 A |
|
Continuous load: | max. 300 | W |
Peak load: | max. 400 | W/0,1 s |
Efficiency ( ): | approx. 90 % | |
Output wave form: | modified sine | |
Overload protection: | >= 320 W | |
Temperature shut off: | at 65 ± 3 °C |
Fuses
Power inverter: | 30 A automotive flat fuse |
Cable fuse: | 30 A automotive flat fuse |
- 3 -