MODEL NAME |
| KONICA MINOLTA RANGE5 |
| |||
Measuring Method |
| Triangulation by light sectioning method |
| |||
| Semiconductor laser λ = 660 nm |
| ||||
Laser Classification |
| Class 2 |
| |||
Sensor |
| Name | CMOS Photo diode |
| ||
| Pixel | 1.31 Mega Pixel (1280 x 1024) |
| |||
|
|
| ||||
Measuring Distance (mm) | 450 to 800 (Distance from | |||||
|
|
|
|
|
| |
| MultiFocus | Distance | 450 |
| 800 | |
|
|
|
|
| ||
| 150 × 188 |
| 267 × 334 | |||
| mode |
|
|
|
| |
| Z | 109 |
| 194 | ||
Measuring | Disabled |
| ||||
Meas. pitch of | 0.16 |
| 0.28 | |||
Range |
|
| ||||
| Distance | 475 |
| 766 | ||
(mm) | MultiFocus |
| ||||
159 × 199 |
| 256 × 320 | ||||
|
| |||||
| mode |
|
|
|
| |
| Z | 109 |
| 194 | ||
| Enabled |
| ||||
|
|
|
|
| ||
|
| Meas. pitch of | 0.08 |
| 0.25 | |
Accuracy (Interglobuler distance) *2 | ±80 μm |
| ||||
Precision (Z, σ)*3 |
| 8 μm |
| |||
Auto Focus |
| available |
| |||
Auto Exposure |
| available |
| |||
Scanning Time |
| about 2 sec. per scan |
| |||
Preview Function |
| available (about 0.4 sec. per scan) |
| |||
Environment Brightness | 500 lx or less |
| ||||
File Format *4 |
| INPUT/OUTPUT: .rgv, .rvm, .rmk (Original format), OUT only: .stl | ||||
Output Interface |
| USB 2.0 HighSpeed |
| |||
Power Supply |
| AC adapter |
| |||
|
| |||||
|
|
|
| |||
External Dimensions (mm) | 295 (W) × 190 (H) × 200 (D) |
| ||||
* exclude the protruding portion of the lens and handle | ||||||
|
|
| ||||
Weight (kg) |
| about 6.7 |
| |||
Operating Condition |
| 10 to 40ºC (relative humidity 65% or less, with no condensation) | ||||
Storage Condition |
| [at 35ºC] , with no | ||||
| condensation) |
| ||||
|
|
|
| |||
Remarks (Controlled Method) | Controlled via dedicated PC software "RANGE VIEWER" |
*1 Due to the difference of origins on the measurement reference surface and measurement data, the Z axis coordinate has an offset of about 120 mm for the measuring distance.
*2 When the interglobuler distance for the ball bars (2 globes) specified in
Our conditions: Temperature 20±1ºC / Distance 450 mm / Warming up 20 mins. / Using the KONICA MINOLTA OPTICS processing software / With Calibration
/Object to be measured: Standard KONICA MINOLTA OPTICS (2 globes) instrument / Position of object to be measured: KONICA MINOLTA OPTICS standard position (10 locations within the measurement space)/ Does not cover the uncertainty over the pricing of the standard instrument.
*3 Measuring conditions: Temperature 20±1ºC / Distance 450 mm / Warming up 20 mins. / Using the KONICA MINOLTA OPTICS processing software / Object to be measured: KONICA MINOLTA OPTICS reference plain chart / 1σ
*4 Using the KONICA MINOLTA OPTICS "RANGE VIEWER" processing software
• The RANGE5 includes the