Operating the VS-66FW

6.4.1Storing an Input/Output Configuration

To store1 the current status in memory, do the following:

1.Press the STO button. The STO button blinks.

2.Press one of the 6 LEAF buttons (this will be the setup # in which the current status is stored). If in the CONFIRM mode, press the blinking TAKE button to confirm the action.

That setup # flashes brightly in the 7-segment Display and the memory stores the data at that reference.

6.4.2Recalling an Input/Output Configuration

To recall a configuration, do the following:

1.Press the RCL button. The RCL button blinks.

2.Press the appropriate LEAF button (the button # corresponding to the setup #). If in the CONFIRM mode, that setup configuration will blink in the 7-segment Display, together with the RCL button and the TAKE button, and will only be implemented after pressing the TAKE button.

The memory recalls the stored data from that reference.

Tip: If you cannot remember which of the 6 configurations is the one that you want, set the VS-66FWto the CONFIRM mode and manually scan all the configurations until you locate it.

6.5 Locking the Front Panel

To prevent changing the settings accidentally or tampering with the unit via the front panel buttons, lock2 your VS-66FW. Unlocking releases the protection mechanism.

To lock the VS-66FW:

￿￿Press and hold the LOCK button until the LOCK button is illuminated The front panel is locked. Pressing a button will have no effect.

To unlock the VS-66FW:

￿￿Press and hold the illuminated LOCK button, until the LOCK button is no longer illuminated

The front panel unlocks

1 Storing a new configuration over a previous configuration (without deleting it first) replaces the previous configuration

2 Nevertheless, even though the front panel is locked you can still operate via RS-232 or RS-485, as well as via the Kramer IR Remote Control Transmitter

15