Operating the
7.1Routing Inputs to Outputs
To route an input to an output:
•Press an OUT key, followed by an IN key to route this input to that output
To route one input to all outputs:
•Press ALL followed by an IN button. The input is routed to all outputs
7.2Disconnecting the Outputs
To disconnect one output:
•Press the OUT button of the output to disconnect and press OFF
To disconnect all outputs at once:
•Press the ALL button and then press OFF. This disconnects all the outputs
7.3Storing and Recalling a Setup
You can use the STO and RCL buttons to store up to 12 setups1 and then recall them, as Figure 3 illustrates:
Figure 3: SELECTOR Buttons2
To store a setup:
1.Set the machine to the desired setup.
For example, press the OUT 3 button and IN 4 button3.
2.Press the STO button. The STO button flashes.
3.Select an OUT or IN SELECT button to store the machine setup (for example, OUT 5).
4.Press the LOCK button4 to store the current setup. In this example, the OUT 5 button stores the setup.
1 IN 1 is used for setup # 1 and OUT 1 is used for setup # 7
2 The gray numbers (1 to 12) in Figure 3 that illustrate the corresponding store/recall configuration numbers, are for the purpose of illustration only and do not actually appear on the buttons
3 You can set all the switcher
4 You have to press the LOCK button within 10 seconds, before the store operation times out
11