Krown Manufacturing KBS300RX instruction manual Cont, Time-Condition-Signal

Models: KBS300RX

1 20
Download 20 pages 41.17 Kb
Page 8
Image 8
CHAPTER 1 (CONT.)

CHAPTER 1 (CONT.)

Keep the battery installed and turn the power switch to OFF before bringing it to the location. Mark on the given label for channel location as fire, mono-carbon, or weather alert and coordinate them with the installed transmitters. This label is available only for the KA300RX.

Hearing Impaired people will need one KBS300RX in their bedroom for the best protection. You can buy many receivers for your needs as long as it still within the 100 feet range. If the house is larger than the range, you will need a wired-fire alarm system. If one triggers the other will trigger also. In this case, the transmitter only needs to be installed on the closest fire alarm to the receiver.

TIME-CONDITION-SIGNAL

When an alarm unit triggers, the red LED on the transmitter will stay lit. The address of the transmitter will be sent to all receivers. After two seconds, if the transmitter continuously sends an alert signal, the KBS300RX receivers will activate the alarm. This Time-Condition-Signal process will prevent a “nuisance” alarm.

Important note: In case of a false alarm, you can turn off the power switch of the receiver and search for which transmitter triggered the alarm by looking for a red LED on each KA300TX. Try to find out what caused the false alarm at the transmitter. If the red LED on the transmitter is OFF or free from the alarm signal source, pressing the reset button on the KBS300RX will turn off the shaker.

FOR HOTEL, DORMITORY OR MULTI-FAMILY HOUSEHOLD

A single fire alarm unit cannot trigger when there is fire or smoke somewhere in the building. The KA300 system will activate the alarm when the alarm system of the hotel, dormitory, or apartment turns on the siren. Therefore, if there is an evacuation signal sent out from the fire alarm center of that building, you will be notified whether you are sleeping or awake, and regardless where you are.

Select only one operation code for your hotel or apartment. Write the code on the cover of this book and keep it for future reference. There are 1022 combinations available for you to pick for each room in your hotel or apartment complex. Keep a record of what combination has been given out to each room so there will not be two rooms operating with the same code.

Install several KA300TX transmitters on the existing alarm siren in the hallway in 50, or 70 feet coverage. Set the channel jumper of those transmitters to channel 3.

4

Page 8
Image 8
Krown Manufacturing KBS300RX instruction manual Cont, Time-Condition-Signal, For Hotel, Dormitory Or Multi-Familyhousehold