Krown Manufacturing KBS300RX instruction manual Cont, Bed Shaker Led Indicator

Models: KBS300RX

1 20
Download 20 pages 41.17 Kb
Page 14
Image 14
BED SHAKER LED INDICATOR

CHAPTER 3 (CONT.)

BED SHAKER LED INDICATOR

INSTALLING THE KA300 SYSTEM FOR FIRST TIME Channel LED

Main LED

Reset Button

1 Main LED:

Turns ON when there is a channel triggered by an alarm in the system.

Low flashing when there is AC power failure.

Fast flashing for battery low warning. It needs to be recharged soon.

2 Channel indicator LEDs:

Turns ON to indicate the corresponding channel has triggered the receiver.

Flashing to indicate a transmitter battery is low.

NOTE:

The supplied battery of KA300TX transmitters can last more than 2 years under normal conditions.

 

If one transmitter battery is getting low, it is recommended that you change all of the

 

transmitter batteries.

KBS300RX is designed to wake you up when the alarm triggered. It will not stop until you are aware of the alarm and recognize the source that caused the alarm. To stop the vibrator on the KBS300RX press the reset button. However if the source continues to send an alarm signal to the bed shaker receiver, the bed shaker will reactivate after a two second pause.

INSTALLING THE KA300 SYSTEM FOR FIRST TIME

Plan the fire alarm system on a drawing with desired channel indicator when the alarm triggers.

Record the operation code to the first page of the manual.

Setup the operation code and channel jumper for all KA300TX transmitters. Turn on and set aside.

Install battery for all receivers KA300RX and KBS300RX.

Plug in power supply.

Do the operation code learning process for each set. Turn the KA300RX on (or hit program button of the KBS300RX). Press and hold the test button on KA300TX for two seconds. One LED on the KA300RX and/or KBS300RX will become stable and the code learning process is finished. If there are several more codes, repeat the above process, if there is only one operation code for all

10

Page 14
Image 14
Krown Manufacturing KBS300RX instruction manual Cont, Bed Shaker Led Indicator, INSTALLING THE KA300 SYSTEM FOR FIRST TIME