PROBLEM: OIL LEAKING AROUND THE EDGES OF THE OIL BATH

3000STOPR005810R082503

TROUBLE SHOOTING

PROBLEM: OIL LEAKING AROUND THE EDGES OF THE OIL BATH

 

 

CAUSE

 

SOLUTION

 

 

INSPECT SHIELD FOR LOOSENESS

 

Carefully tighten wing nuts or adjust locking fasteners that hold

 

 

 

 

shield in place, hand tighten only. Check for foreign material

 

 

 

 

between the foam gasket and shield.

 

 

DAMAGEDORLOOSEGASKETMATERIALAROUNDENCLOSURESHIELD

 

Remove shield and check gasket material for proper adhesion to

 

 

 

 

the mating panel of mixer. If gasket adhesive has come loose

 

 

 

 

from front panel, replace gasket.

 

 

 

 

 

 

 

PROBLEM: HYDRAULIC DOOR SYSTEM OPERATES ERRATICALLY

 

 

 

 

 

 

 

CAUSE

 

SOLUTION

 

 

 

 

 

 

COMPONENTS STICKING OR BINDING

 

Check for hydraulic oil contamination, dirt, or gummy deposits. If

 

 

 

 

dirt is found, search and repair the source. Check for worn or

 

 

 

 

bent parts. Check oil level in hydraulic system.

 

INADEQUATE FLOW OR PRESSURE FROM HYDRAULIC SYSTEM.

 

Check fluid and fill to proper level.

 

OIL IS LEAKING PAST SEALS IN CYLINDERS OR VALVES

 

Install seal kits to repair worn seals. See parts listing for part

 

 

 

 

numbers.

 

 

 

 

 

 

 

 

 

 

 

PROBLEM: SCALE HANGS UP, LOAD CELL ONLY

 

 

 

 

 

 

 

CAUSE

 

SOLUTION

 

 

 

 

 

LOAD CELL NOT VERTICAL

 

Load cell should be vertical, if not first inspect check arm

 

 

 

 

assembly and or pin check assembly. Second adjust by

 

 

 

 

loosening top load cell mount in a no load condition, adjust load

 

 

 

 

cell to a vertical position and tighten fasteners.

 

PIN CHECK OUT OF ADJUSTMENT

 

Remove pin check assembly, test scale, if scale operates

 

 

 

 

properly clean or repair pin check assembly. Also see “INSPEC-

 

 

 

 

TIONS AND ADJUSTMENTS SECTION”

 

SWING ARM NOT LUBRICATED

 

lubricate check arm (should rotate on sockets without great

 

 

 

 

effort). Also see “INSPECTIONS AND ADJUSTMENTS SECTION”

 

 

 

 

 

 

 

 

 

 

PROBLEM: SCALE WEIGHS VERY HEAVY OR VERY LIGHT, WEIGH BAR ONLY

 

 

 

 

 

 

 

CAUSE

 

SOLUTION

 

 

 

 

 

IMPROPER CALIBRATION

 

CALIBRATE SCALE refer to scale operators manual for informa-

 

 

 

 

tion

 

DAMAGED CABLE ON ONE OR MORE LOAD CELLS

 

Inspect cables and repair or replace as necessary.

 

 

 

 

 