La Crosse Technology WS-8300U instruction manual Iii.Mounting

Models: WS-8300U

1 12
Download 12 pages 37.74 Kb
Page 8
Image 8

displayed. If they are not shown in LCD after 60 seconds, remove the batteries and wait for at least 60 seconds before reinserting them.

4.The outdoor temperature and humidity from the first sensor (channel 1) should then be displayed on the Weather station. If this does not happen and the signal reception icon is not shown, after 2 minutes, the batteries will need to be removed from both units and reset from step 1.

5.Insert the batteries to the second sensor as soon as the outdoor temperature and humidity readings from the first sensor are displayed on the Weather station.

NOTE: You must insert the batteries into the second sensor within 30 seconds of reception of the first sensor.

6.The outdoor temperature and humidity from the second sensor and the "channel 2" icon should then be displayed on the Weather station. If this does not happen after 2 minute, the batteries will need to be removed from all the units and reset from step 1.

7.Insert the batteries to the third sensor as soon as the "channel 2" icon and outdoor data are displayed on the Weather station. Then within 2 minutes, the channel 3 outdoor data from the third sensor will be displayed and the channel icon will shift back to "1" once the third sensor is successfully received. If this is not happen, user shall restart the setting up from step 1.

NOTE: You must insert the batteries into the third sensor within 30 seconds of reception of the second sensor.

IMPORTANT: Transmission problems will arise if the setting for multiple sensors is not followed as described above. Should transmission problems occur, it is necessary to remove the batteries from all units and start again the set-up from step 1.

D. VIEWING AND OPERATING WITH MULTIPLE REMOTE SENSOR UNITS

1.To view the temperature of a different thermo-hygro sensor unit, press and release the SET/CH button. A shift from one “boxed” number to the next should be observed on the right side of the OUTDOOR LCD.

2.To view the Minimum/Maximum temperature & humidity : first select from which thermo-hygro sensor to read data (indicated by the “boxed” number). Pressing and releasing the MIN/MAX button will toggle through the minimum and maximum indoor temperature, and the minimum and maximum outdoor temperature and humidity.

3.To reset the Minimum/Maximum readings, press and hold the MIN/MAX button for 5 seconds.

III.MOUNTING

Note: To achieve a true temperature reading, avoid mounting in direct sunlight. We recommend that you mount the thermo-hygro sensor on an outside North-facing wall (under the eve of a house is ideal). The sending range is 330 feet; obstacles such as walls, stucco walls, concrete, and large metal objects will reduce the range. Place the Wireless Weather Station and thermo-hygro sensor in their desired locations before