DDC2 / | Digital Display Wall Clock Guide | Page 22 |
3-Wire Synchronous (115VAC)
H
M
BLK | BLK |
| Run |
| ||
115VAC |
|
| ||
AC Return | ||||
From |
| |||
Master Clock |
| Correction | ||
|
|
|
|
Clock will correct minutes hourly at HH:59 and hour and minutes twice daily at 5:59.
Wiring applies to secondary wall clocks such as:
Lathem type SS Cincinnati D10 IBM 77 Series
Simplex 77 Series,
Stromberg 3000
BRN / WHT | BLU / WHT |
To
Other Clocks
Set switches
Indicates depressed side of switch
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
OPEN