Page 29

Digital Display Wall Clock Guide

DDC2 / 4-RS Wiring

Synchronous Wired

H

M

BLK

BLK

 

 

Run

 

115VAC

 

AC Return

 

From

 

Master Clock

 

Correction

 

 

 

 

Clock will correct minutes hourly at HH:58 and hour and minutes twice daily beginning at 5:05.

For 24VAC applications, use wiring shown on page 18

Wiring applies to secondary wall clocks such as:

Cincinnati D8 Faraday

Honeywell ST402A

BRN / WHT

BLU / WHT

To

Other Clocks

Set switches 1-5 of S1 as shown.

Indicates depressed side of switch

1

2

3

4

5

6

7

8

OPEN

Page 35
Image 35
Lathem DDC4, DDC2 manual Brn / Wht Blu / Wht, Synchronous Wired