Page 31 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring
Simplex 45th Minute Dual Motor
115VAC
From
Master Cloc
k
To
Other Clocks
H
M
BLU / WHT
Run
Correction
BRN / WHT
BLK
BLK
AC Return
Clock must be set to proper hour. Clock will
correct minutes hourly at HH:45. . Use of a 9Volt
alkaline battery is recommended to avoid resets
For 24VAC applications, use
wiring shown on page 18
678
Set switches 1-5 of S1 as shown.
Indicates depressed side of switch
OPEN
123 4 5