TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM

TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM

Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.

 

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

1.

Spark igniter will not light pilot after

A. Defective igniter

Check the gap between the electrode and pilot. It should

 

repeated triggering of igniter button.

(no spark at electrode).

be between 1/8” and 3/16." If the gap is out of this

 

 

 

range, adjust the gap or replace the pilot.

 

 

 

 

 

 

B. Defective or misaligned electrode at pilot

Using a match, light pilot. If pilot lights, turn off pilot

 

 

(spark at electrode).

and trigger the igniter button again. If pilot lights, an

 

 

 

improper gas mixture caused the bad lighting and a

 

 

 

longer purge period is recommended. If pilot will not

 

 

 

light – check gap at electrode and pilot – It should

 

 

 

be between 1/8” and 3/16." If the gap is out of this

 

 

 

range, adjust the gap or replace the pilot. (Figure 18

 

 

 

on page 9 ).

 

 

C. Gas supply pressure errant.

Check inlet gas pressure. It should be within the limits

 

 

 

as marked on the rating plate.

 

 

D. Pilot orifice plugged.

Clean or replace pilot orifice.

 

 

 

 

2.

Pilot will not stay lit after

A. Defective pilot generator

Check pilot flame, it must impinge on thermocouple

 

carefully following the lighting

(thermocouple).

(Figure 18 on page 9 ). Clean and/or adjust pilot for

 

instructions.

 

maximum flame impingement on thermocouple.

 

 

 

Ensure that the connection between the valve and

 

 

 

thermocouple are tight and secure.

 

 

 

 

3.

Pilot burning, no gas to burner, Valve

A. Wall switch or wires defective.

Check wall switch and wires for proper connections.

 

knob “ON,” Wall Switch “ON.”

 

Jumper wire across terminals at wall switch, if burner

 

 

 

comes on, replace defective wall switch. If okay, jumper

 

 

 

wires across wall switch wires at valve, if burner comes

 

 

 

on, wires are faulty or connections are bad.

 

 

B. Thermopile may not be generating suf-

Check thermopile with millivolt meter. Take reading

 

 

ficient millivoltage.

at thermopile terminals of gas valve. Should read

 

 

 

325 millivolts minimum with optional wall switch

 

 

 

“OFF.” Replace faulty thermopile if reading is below

 

 

 

specified minimum.

 

 

C. Plugged burner orifice.

Check burner orifice for stoppage and remove.

 

 

 

 

4.

Frequent pilot/burner outage prob-

A. Pilot flame may be too low or blowing (high)

Clean and/or adjust pilot flame for maximum flame

 

lem.

causing the pilot/valve safety to drop out.

impingement on thermocouple (Figure 18 on page

 

 

 

9 ).

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.