41653_model43558.pmd

6

 

 

Read This Before Installing Thermostat

6

 

 

 

 

 

 

 

 

IMPORTANT

COMPRESSOR PROTECTION

 

 

 

Read the entire installation section of this Owner’s Manual

The thermostat provides a 3.5 minute delay after shutting off

 

 

 

1thoroughly before you begin to install or operate your Cli-

5the heating or cooling system before it can be restarted.

 

 

 

mate Technology Thermostat.

This feature will prevent damage to your compressor caused

 

 

 

INSTALLATION

by rapid cycling.

 

 

 

 

 

 

 

 

All installation is normally performed at your

TEMPERATURE RANGE

 

 

 

2thermostat.

Your thermostat can be programmed between 45°F and 95°F

 

 

 

ARMCHAIR PROGRAMMING

6(7°C and 35°C). However, it will display room temperatures

 

 

 

You can program your thermostat before installation by in-

from 15°F to 99°F (-9°C and 37°C). “HI” will be displayed if

 

 

 

the temperature is higher than 99°F (37°C), and “LO” will be

 

 

 

3serting the batteries and following the instructions starting

displayed if the temperature is lower than 15°F (-9°C).

 

 

 

on page 18. This can be done while you relax in your favorite

 

 

 

 

 

chair and is a very good way to familiarize yourself with all the

AUTO RECOVERY

 

 

 

functions of your Climate Technology Thermostat.

Your thermostat is set from the factory to gradually recover

 

 

 

SYSTEM COMPATIBILITY

7the room temperature from an energy saving program to

 

 

 

Your Thermostat is designed to operate these

your comfort program. Therefore, the thermostat may turn your

 

 

 

system on several minutes prior to your programmed time. This

 

 

 

424-Volt systems:

operation is normal, but can be turned off. Refer to the Options

 

 

 

Multi-stage heat pumps with auxiliary heat

Menu information on pages 18-21.

 

 

 

Multi-stage systems (2 stage heat, 2 stage cool)

 

 

 

 

 

This thermostat will not control 120/240 Volt systems or

 

 

 

 

 

millivolt systems.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

OPERATION

8This system operates on your system’s 24 Volt power supply. The supply is monitored by the thermostat, and it will stop functioning if AC power is lost. (When using backup batteries, “No AC Pwr” will be displayed.) All system controls will remain

off until power is restored.

NOTE: The INDIGLO® Night-Light will not function when AC power is lost.

NOTE: Any remote temperature sensors (if used on your system) will not operate when AC power is lost.

BATTERY WARNING

9Batteries may be used optionally to prevent the loss of your thermostat’s clock, programs and options due to a power outage. However, when the batteries become drained, a low battery warning will appear on the display. When this message occurs, install 2 new AAA batteries. You have approximately 30

seconds when changing the batteries to keep thermostat’s clock and program settings.

NOTE: The default system selection at power-on is HEAT. Batteries are recommended to prevent an undesired system change due to a power outage.