41653_model43558.pmd
6
|
| Read This Before Installing Thermostat | 6 |
|
|
|
|
|
| ||
|
| IMPORTANT | COMPRESSOR PROTECTION |
| |
|
| Read the entire installation section of this Owner’s Manual | The thermostat provides a 3.5 minute delay after shutting off |
| |
|
| 1thoroughly before you begin to install or operate your Cli- | 5the heating or cooling system before it can be restarted. |
| |
|
| mate Technology Thermostat. | This feature will prevent damage to your compressor caused |
| |
|
| INSTALLATION | by rapid cycling. |
| |
|
|
|
|
| |
|
| All installation is normally performed at your | TEMPERATURE RANGE |
| |
|
| 2thermostat. | Your thermostat can be programmed between 45°F and 95°F |
| |
|
| ARMCHAIR PROGRAMMING | 6(7°C and 35°C). However, it will display room temperatures |
| |
|
| You can program your thermostat before installation by in- | from 15°F to 99°F |
| |
|
| the temperature is higher than 99°F (37°C), and “LO” will be |
| ||
|
| 3serting the batteries and following the instructions starting | displayed if the temperature is lower than 15°F |
| |
|
| on page 18. This can be done while you relax in your favorite |
|
|
|
|
| chair and is a very good way to familiarize yourself with all the | AUTO RECOVERY |
| |
|
| functions of your Climate Technology Thermostat. | Your thermostat is set from the factory to gradually recover |
| |
|
| SYSTEM COMPATIBILITY | 7the room temperature from an energy saving program to |
| |
|
| Your Thermostat is designed to operate these | your comfort program. Therefore, the thermostat may turn your |
| |
|
| system on several minutes prior to your programmed time. This |
| ||
|
| operation is normal, but can be turned off. Refer to the Options |
| ||
|
| ■ | Menu information on pages |
| |
|
| ■ |
|
|
|
|
| This thermostat will not control 120/240 Volt systems or |
|
|
|
|
| millivolt systems. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7
OPERATION
8This system operates on your system’s 24 Volt power supply. The supply is monitored by the thermostat, and it will stop functioning if AC power is lost. (When using backup batteries, “No AC Pwr” will be displayed.) All system controls will remain
off until power is restored.
NOTE: The INDIGLO® Night-Light will not function when AC power is lost.
NOTE: Any remote temperature sensors (if used on your system) will not operate when AC power is lost.
BATTERY WARNING
9Batteries may be used optionally to prevent the loss of your thermostat’s clock, programs and options due to a power outage. However, when the batteries become drained, a low battery warning will appear on the display. When this message occurs, install 2 new AAA batteries. You have approximately 30
seconds when changing the batteries to keep thermostat’s clock and program settings.
NOTE: The default system selection at