BLOWER RELAY | CHANGING BLOWER SPEED | |
| ||
5 | BLOWER RELAY | PLASTIC CAPS |
|
| |
| HARNESS |
|
| BLUE (MED) | RED (L0) |
2 |
|
|
|
| BLACK (HI) |
|
| YELLOW (COM) |
Figure 13. Changing Blower Speed
NOTE — Refer to wiring diagram located on the unit access panel (or figure 13 above) and blower performance (table 2).
SAll air data measured external to unit with 1 inch
SAll factory settings are medium speed except the
SAll data given while air handler is operating with a dry DX coil.
Table 2. CBX25UH Blower Performance
Air Handler | Blower Speed | .10” WC | .20” WC | .30” WC | .40” WC | .50” WC | |
Model | |||||||
|
|
|
|
|
| ||
| Low (Red) | 510 | 495 | 475 | 420 | 325 | |
18 | Med (Blue) | 670 | 650 | 630 | 595 | 505 | |
| High (Black) | 905 | 865 | 820 | 770 | 705 | |
| Low (Red) | 630 | 625 | 615 | 610 | 580 | |
24 | Med (Blue) | 885 | 875 | 850 | 820 | 780 | |
| High (Black) | 1130 | 1100 | 1070 | 1010 | 950 | |
| Low (Red) | 900 | 865 | 830 | 780 | 740 | |
30 | Med (Blue) | 1075 | 1060 | 1030 | 985 | 940 | |
| High (Black) | 1240 | 1210 | 1170 | 1135 | 1085 | |
| Low (Red) | 1160 | 1140 | 1115 | 1085 | 990 | |
36 | Med (Blue) | 1500 | 1445 | 1385 | 1300 | 1200 | |
| High (Black) | 1660 | 1575 | 1495 | 1405 | 1390 | |
| Low (Red) | 1325 | 1315 | 1300 | 1275 | 1225 | |
42 | Med (Blue) | 1490 | 1465 | 1440 | 1395 | 1315 | |
| High (Black) | 1820 | 1770 | 1690 | 1600 | 1500 | |
| Low (Red) | 1775 | 1710 | 1645 | 1565 | 1470 | |
48 | Med (Blue) | 1995 | 1895 | 1800 | 1685 | 1560 | |
| High (Black) | 2070 | 1970 | 1850 | 1719 | 1595 | |
| Low (Red) | 1675 | 1630 | 1580 | 1520 | 1450 | |
60 | Med (Blue) | 1965 | 1925 | 1875 | 1800 | 1695 | |
| High (Black) | 2140 | 2085 | 2000 | 1895 | 1795 |
SBlower Performance (CFM vs. ESP inches H2O)
SCooling speeds should not be reduced below factory setting.
SUnits with electric heat approved at 0.5” maximum and medium blower speed minimum.
Page 11