Lenovo 28155YU, 28155XU manual Strategy for replacing a hard disk drive, How to use error message

Models: 2808DKU 28155XU 28155YU

1 184
Download 184 pages 58.83 Kb
Page 48
Image 48

Use the following strategy to prevent unnecessary expense for replacing and servicing FRUs:

vIf you are instructed to replace a FRU but the replacement does not correct the problem, reinstall the original FRU before you continue.

vSome computers have both a processor board and a system board. If you are instructed to replace either the processor board or the system board, and replacing one of them does not correct the problem, reinstall that board, and then replace the other one.

vIf an adapter or a device consists of more than one FRU, any of the FRUs may be the cause of the error. Before replacing the adapter or device, remove the FRUs, one by one, to see if the symptoms change. Replace only the FRU that changed the symptoms.

Attention: The setup configuration on the computer you are servicing may have been customized. Running Automatic Configuration may alter the settings. Note the current configuration settings (using the View Configuration option); then, when service has been completed, verify that those settings remain in effect.

Strategy for replacing a hard disk drive

Always try to run a low-level format before replacing a hard disk drive. This will cause all customer data on the hard disk to be lost. Be sure that the customer has a current backup of the data before doing this task.

Attention: The drive startup sequence in the computer you are servicing may have been changed. Be extremely careful during write operations such as copying, saving, or formatting. If you select an incorrect drive, data or programs can be overwritten.

Important notice for replacing a system board

Some components mounted on a system board are very sensitive. Improper handling of a system board can cause damage to those components, and may cause a system malfunction.

Attention: When handling a system board:

vDo not drop a system board or apply any excessive force to it.

vAvoid rough handling of any kind.

vAvoid bending a system board and hard pushing to prevent cracking at each BGA (Ball Grid Array) chipset.

How to use error message

Use the error codes displayed on the screen to diagnose failures. If more than one error code is displayed, begin the diagnosis with the first error code. Whatever causes the first error code may also cause false error codes. If no error code is displayed, see whether the error symptom is listed in the Symptom-to-FRU Index for the computer you are servicing.

40ThinkPad T400s Hardware Maintenance Manual

Page 48
Image 48
Lenovo 28155YU, 28155XU, 2808DKU Strategy for replacing a hard disk drive, Important notice for replacing a system board