Technical Information
Error Messages
Message | Cause(s) | Action(s) | |
|
|
|
|
Lamp Startup Fail | The lamp has not started after being | • | Check lamp |
| struck. | • | Check lamp socket and wiring |
|
| • Check ballast and igniter | |
|
|
|
|
Temperature Sense Fail | There is no communication with | • | Check sensor wiring |
| temperature sensor. | • | Check sensor integrity |
|
| • | Check control board |
Lamp Hot Protection | Fixture temperature is higher than 105º C; | • | Check fans |
| lamp was switched to low power for safety. | • | Check fan wiring |
|
| • | Clean vents |
|
|
|
|
Lamp Hot Power Off | Fixture temperature is 110º C or higher; | • | Check fans |
| lamp was switched to off for safety. | • | Check fan wiring |
|
| • | Clean vents |
Maintenance Fixture | Fixture Maintenance timer expired. | • | Proceed with maintenance and reset timer |
Lamp On Over 700 Hour | Lamp change is overdue. | • | Change lamp |
|
|
|
|
Memory Initial Fail | Memory chip error found. | • | Change main board |
|
|
|
|
Fan 1 Error | The indicated fan is not working. | • | Check fan |
Fan 2 Error |
| • | Check fan wiring |
Fan 3 Error |
|
|
|
Fan 4 Error |
|
|
|
Fan 5 Error |
|
|
|
Fan 6 Error |
|
|
|
There is no communication with the | • | Check sensors’ wiring and position | |
indicated auxiliary CPU. | • | Check stepper motor, belt, and driver board | |
| • | Check control boards | |
|
|
| |
CPU F Error |
|
|
|
CPU G Error |
|
|
|
CPU H Error |
|
|
|
|
|
|
|
Pan Home Sensor Error | The moving head failed going to home | • | Check moving head’s free movement |
Pan Encode Error | position after power up or fixture reset. | • | Check sensors’ wiring and position |
Tilt Home Sensor Error |
| • | Check stepper motor, belt ,and driver board |
Tilt Encode Error |
| • | Check the corresponding control board |
|
| • Check main control board | |
|
|
|
|
Color 1 Reset Fail | The indicated moving part failed going to | • | Check part’s free movement and integrity |
Cyan Reset Fail | home position after power up or fixture | • | Check sensors’ wiring and position |
Magenta Reset Fail | reset. | • | Check stepper motor, belt, and driver board |
Yellow Reset Fail |
| • | Check the corresponding control board |
3200 K Filter Reset Fail |
| • | Check main control board |
Gobo 1 Reset Fail |
|
|
|
|
|
| |
Gobo 2 Reset Fail |
|
|
|
|
|
| |
Iris Reset Fail |
|
|
|
Effect Reset Fail |
|
|
|
|
|
| |
Frost Reset Fail |
|
|
|
Focus Reset Fail |
|
|
|
Zoom Reset Fail |
|
|
|
|
|
|
|
Legend™ 1200E Spot User Manual Rev. 03c |