Inthefollowingindex,Xcanrepresentanynumber.
DiagnosticerrorcodeFRU/Action
000-000-XXXBIOSTestPassedNoaction
000-002-XXXBIOSTimeout1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-024-XXXBIOSAddressingtestfailure1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-025-XXXBIOSChecksumValueerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-026-XXXFLASHdataerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-027-XXXBIOSCon��guration/Setuperror1.RunSetup
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
3.Systemboard
000-034-XXXBIOSBufferAllocationfailure1.Rebootthesystem
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
3.Runmemorytest
4.Systemboard
000-035-XXXBIOSResetConditiondetected1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-036-XXXBIOSRegistererror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-038-XXXBIOSExtensionfailure1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Adaptercard
3.Systemboard
000-039-XXXBIOSDMIdataerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
000-195-XXXBIOSTestabortedbyuserInformationonlyRe-startthetest,ifnecessary
000-196-XXXBIOStesthalt,errorthresholdexceeded1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
44ThinkCentreHardwareMaintenanceManual