DiagnosticerrorcodeFRU/Action
001-038-XXXSystemExtensionfailure1.Adaptercard
2.Systemboard
001-039-XXXSystemDMIdatastructureerror1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Systemboard
001-040-XXXSystemIRQfailure1.Power-off/onsystemandre-test
2.Systemboard
001-041-XXXSystemDMAfailure1.Power-off/onsystemandre-test
2.Systemboard
001-195-XXXSystemTestabortedbyuserInformationonlyRe-startthetest,ifnecessary
001-196-XXXSystemtesthalt,errorthresholdexceeded1.PressF3toreviewthelogle
2.Re-startthet esttoresetthelogle
001-197-XXXSystemtestwarning1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6“Using
theSetupUtilityprogram”onpage39
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
001-198-XXXSystemtestaborted1.Ifacomponentiscalledout,makesureitis
connectedand/orenabled.SeeChapter6“Using
theSetupUtilityprogram”onpage39
2.Flashthesystemandretest.See“Updating(ashing)
BIOSfromadisc”onpage203
3.Goto“Undeterminedproblems”onpage65
001-199-XXXSystemtestfailed,causeunknown1.Goto“Undeterminedproblems”onpage65
2.Flashthesystemandre-test
3.Replacecomponentunderfunctiontest
001-250-XXXSystemECCerrorSystemboar d
001-254-XXX001-255-XXX001-256-XXX001-257-XXX
SystemDMAerror
Systemboard
001-260-XXX001-264-XXXSystemIRQerrorSystemboard
001-268-XXXSystemIRQ1failure1.DeviceonIRQ1
2.Systemboard
001-269-XXXSystemIRQ2failure1.DeviceonIRQ2
2.Systemboard
001-270-XXXSystemIRQ3failure1.DeviceonIRQ3
2.Systemboard
001-271-XXXSystemIRQ4failure1.DeviceonIRQ4
2.Systemboard
001-272-XXXSystemIRQ5failure1.DeviceonIRQ5
2.Systemboard
46ThinkCentreHardwareMaintenanceManual