DiagnosticerrorcodeFRU/Action
086-199-XXXMousePortinterfacetestfailed,cause
unknown
1.See“Undeterminedproblems”onpage65
2.Flashthesystemandre-test.See“Updating
(ashing)BIOSfromadisc”onpage203
3.Replacecomponentunderfunctiontest
089-000-XXXMicroprocessorTestPassedNoaction
089-XXX-XXXMicroprocessorfailure1.Microprocessor(s)
2.Systemboard
089-195-XXXMicroprocessorTestabortedbyuserInformationonlyRe-startthetest,ifnecessary
089-196-XXXMicroprocessortesthalt,errorthreshold
exceeded
1.PressF3tor eviewthelogle
2.Re-startthetesttoresetthelogle
089-197-XXXMicroprocessortestwarning1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6“Using
theSetupUtilityprogram”onpage39
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
089-198-XXXMicroprocessortestaborted1.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage203
2.Goto“Undeterminedproblems”onpage65
089-199-XXXMicroprocessortestfailed,causeunknown1.See“Undeterminedproblems”onpage65
2.Flashthesystemandre-test.See“Updating
(ashing)BIOSfromadisc”onpage203
3.Replacecomponentunderfunctiontest
170-000-XXXVoltageSensor(s)TestPassedNoaction
170-0XX-XXXVoltageSensor(s)failure1.Flashsystem
2.Systemboard
170-195-XXXVoltageSensor(s)TestabortedbyuserInformationonlyRe-startthetest,ifnecessary
170-196-XXXVoltageSensor(s)testhalt,errorthreshold
exceeded
1.PressF3tor eviewthelogle
2.Re-startthetesttoresetthelogle
170-197-XXXVoltageSensor(s)testwarning1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6“Using
theSetupUtilityprogram”onpage39
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
170-198-XXXVoltageSensor(s)testaborted1.Ifacomponentiscalledout,makesureitis
connectedand/orenabled.SeeChapter6“Using
theSetupUtilityprogram”onpage39
2.Flashthesystemandre-test.See“Updating
(ashing)BIOSfromadisc”onpage203
3.Goto“Undeterminedproblems”onpage65
58ThinkCentreHardwareMaintenanceManual