Lenovo 4468, 4471, 4466, 4498, 4480, 4485, 4474, 4496, 4477, 4497, 4476 Diagnostic Error Code FRU/Action

Models: 4476 4499 4485 4497 4480 4471 4496 4479 4495 4498 4466 4468 4477 4473 4474

1 486
Download 486 pages 62.53 Kb
Page 73
Image 73

Diagnostic Error Code

FRU/Action

 

 

170-199-XXXVoltage Sensor(s) test failed, cause

1. See “Undetermined problems” on page 71

unknown

2.

Flash the system and re-test. See “Updating

 

 

 

(flashing) the BIOS from a disc” on page 469

 

3.

Replace component under function test

 

 

170-250-XXX170-251-XXXVoltage Sensor(s) Voltage

1. Power supply

limit error

2.

System board

 

 

 

170-254-XXXVoltage Sensor(s) Voltage Regulator

1. Voltage Regulator Module (VRM)

Module error

2.

Microprocessor

 

 

3.

System board

 

 

175-000-XXXThermal Sensor(s) Test Passed

No action

 

 

175-0XX-XXXThermal Sensor(s) failure

1. Flash system

 

2.

System board

 

 

175-195-XXXThermal Sensor(s) Test aborted by user

Information only Re-start the test, if necessary

 

 

 

175-196-XXXThermal Sensor(s) test halt, error threshold

1.

Press F3 to review the log file

exceeded

2.

Re-start the test to reset the log file

 

 

 

175-197-XXXThermal Sensor(s) test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility program” on page 43

 

2.

Re-run test

 

3.

Replace the component that is called out in warning

 

 

statement

 

4.

Replace the component under test

 

 

175-198-XXXThermal Sensor(s) test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS from a disc” on page 469

 

3.

Go to “Undetermined problems” on page 71

 

 

175-199-XXXThermal Sensor(s) test failed, cause

1. See “Undetermined problems” on page 71

unknown

2.

Flash the system and re-test. See “Updating

 

 

 

(flashing) the BIOS from a disc” on page 469

 

3.

Replace component under function test

 

 

175-250-XXX175-251-XXXThermal Sensor(s) limit error

1. Check fans

 

2.

Check Power supply voltages

 

3.

Microprocessor

 

4.

System board

 

 

185-000-XXXAsset Security Test Passed

No action

 

 

185-XXX-XXXAsset Security failure

1. Flash system

 

2.

System board

 

 

185-278-XXXAsset Security Chassis Intrusion

1. Assure Asset Security Enabled

 

2.

C2 Cover Switch

 

3.

System board

 

 

201-000-XXXSystem Memory Test Passed

No action

 

 

 

Chapter 7. Symptom-to-FRU index 65