Product overview
FRU | Applicable test | |
|
| |
Hard disk drive | Enter the BIOS Setup Utility and change Serial ATA (SATA) setting | |
| to Compatibility, then run Diagnostics | |
|
|
|
Diskette drive | 1. | Diagnostics |
| 2. | Interactive Tests |
|
| |
1. Diagnostics | ||
drive | 2. | Interactive Tests |
|
|
|
Memory | 1. | If two DIMMs are installed, remove one of them and run |
|
| Diagnostics |
| 2. | If the problem does not recur, return the DIMM to its place, |
|
| remove the other one, and run the test again. |
| 3. | If the test does not detect the error, run Diagnostics |
|
| Memory Test - Full. |
| Note: The maximum supported memory size is 3GB. | |
|
|
|
Fan | 1. | Turn on the computer and check the air turbulence at the |
|
| louver near the power switch. |
| 2. | Run Diagnostics |
|
|
|