Product overview
FRU tests
The following table shows the test for each FRU.
FRU | Applicable test | |
|
|
|
System board | 1. | Diagnostics |
| 2. | Diagnostics |
| 3. | If the docking station or the port replicator is attached to the |
|
| ThinkPad computer, undock it. Place the computer on a |
|
| horizontal surface, and run Diagnostics |
|
| |
| Note: Do not apply any physical shock to the computer while the | |
| test is running. | |
|
| |
Power | Diagnostics | |
| (Battery 2) | |
|
|
|
LCD unit | 1. | Diagnostics |
| 2. | Interactive Tests |
|
|
|
Modem, MDC1.5 | 1. | Make sure the modem is set up correctly. |
| 2. | Replace the modem jack and the modem card in turn, and run |
|
| the following test in Diagnostics |
|
| a. Conexant Smart Modem Interrupt |
|
| b. Conexant Smart Modem Dialtone |
|
| |
Audio | Enter the BIOS Setup Utility and change Serial ATA (SATA) setting | |
| to Compatibility, and run Diagnostics | |
| Analog Devices HDA CODEC Test | |
|
| |
Speaker | Interactive Tests | |
| Note: (For X61/X61s only) Once Modem/Audio test is done, if no | |
| sound is heard in this test, turn the computer off and on. Then, run | |
| this test again. | |
|
| |
PC Card slot | Diagnostics | |
|
|
|
Keyboard | 1. | Diagnostics |
| 2. | Interactive Tests |
|
| |
TrackPoint or pointing | If the TrackPoint does not work, check the configuration as | |
device | specified in the BIOS Setup Utility. If the TrackPoint is disabled, | |
| select Enable to enable it. | |
| After you use the TrackPoint, the pointer may drift on the screen | |
| for a short time. This drift can occur when a slight, steady pressure | |
| is applied to the TrackPointing Stick. This symptom is not a | |
| hardware problem. If the pointer stops after a short time, no | |
| service action is necessary. | |
| If enabling the TrackPoint does not correct the problem, continue | |
| with the following: | |
| v Interactive Tests |
(continued)