Lenovo 4220, 4222, 4215 Diagnostic Error Code, FRU/Action, XXX Game Port interface test warning

Models: 4221 4219 4215 4222 4220

1 178
Download 178 pages 48.44 Kb
Page 65
Image 65

Diagnostic Error Code

FRU/Action

 

 

080-197-XXXGame Port interface test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

080-198-XXXGame Port interface test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

080-199-XXXGame Port interface test failed, cause

1. See “Undetermined problems” on page 67.

unknown

2.

Flash the system and re-test. See “Updating

 

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

086-000-XXXMouse Port interface Test Passed

No action

 

 

086-001-XXXMouse Port interface Presence

1. Mouse

 

2.

System board

 

 

086-032-XXXMouse Port interface Device controller failure

1. Mouse

 

2.

System board

 

 

086-035-XXXMouse Port interface Reset

1. Mouse

 

2.

System board

 

 

086-040-XXXMouse Port interface IRQ failure

1. Run the Setup Utility program.

 

2.

Mouse

 

3.

System board

 

 

086-195-XXXMouse Port interface Test aborted by user

Information only Restart the test, if necessary.

 

 

 

086-196-XXXMouse Port interface test halt, error

1.

Press F3 to review the log file.

threshold exceeded

2.

Restart the test to reset the log file.

 

 

 

086-197-XXXMouse Port interface test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

086-198-XXXMouse Port interface test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

 

Chapter 8. Symptom-to-FRU Index 59

Page 65
Image 65
Lenovo 4220, 4222, 4215, 4219, 4221 manual Diagnostic Error Code, FRU/Action, XXX Game Port interface test warning