Diagnostic Error Code

FRU/Action

 

 

015-196-XXXUSB port test halt, error threshold exceeded

1. Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

015-197-XXXUSB port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

015-198-XXXUSB port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

015-199-XXXUSB port test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

018-000-XXXPCI Card Test Passed

No action

 

 

 

018-0XX-XXXPCI Card Failure

1.

Riser card, if installed.

 

2.

System board

 

 

018-195-XXXPCI Card Test aborted by user

1. PCI card

 

2.

Information only Restart the test, if necessary

 

 

018-196-XXXPCI Card test halt, error threshold exceeded

1. Press F3 to review the log file

 

2.

Restart the test to reset the log file

 

 

018-197-XXXPCI Card test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

018-198-XXXPCI Card test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

018-199-XXXPCI Card test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

 

54Hardware Maintenance Manual

Page 60
Image 60
Lenovo 4220, 4222, 4215, 4219, 4221 manual Diagnostic Error Code FRU/Action