Lenovo 4220, 4222, 4215, 4219 Diagnostic Error Code, FRU/Action, Press F3 to review the log file

Models: 4221 4219 4215 4222 4220

1 178
Download 178 pages 48.44 Kb
Page 60
Image 60

Diagnostic Error Code

FRU/Action

 

 

015-196-XXXUSB port test halt, error threshold exceeded

1. Press F3 to review the log file.

 

2.

Restart the test to reset the log file.

 

 

015-197-XXXUSB port test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

015-198-XXXUSB port test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

015-199-XXXUSB port test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

018-000-XXXPCI Card Test Passed

No action

 

 

 

018-0XX-XXXPCI Card Failure

1.

Riser card, if installed.

 

2.

System board

 

 

018-195-XXXPCI Card Test aborted by user

1. PCI card

 

2.

Information only Restart the test, if necessary

 

 

018-196-XXXPCI Card test halt, error threshold exceeded

1. Press F3 to review the log file

 

2.

Restart the test to reset the log file

 

 

018-197-XXXPCI Card test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

018-198-XXXPCI Card test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

018-199-XXXPCI Card test failed, cause unknown

1. Go to “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

 

54Hardware Maintenance Manual