Lenovo 4222, 4220, 4215 Diagnostic Error Code, FRU/Action, See “Undetermined problems” on page

Models: 4221 4219 4215 4222 4220

1 178
Download 178 pages 48.44 Kb
Page 66
Image 66

Diagnostic Error Code

FRU/Action

 

 

086-199-XXXMouse Port interface test failed, cause

1. See “Undetermined problems” on page 67.

unknown

2.

Flash the system and re-test. See “Updating

 

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

089-000-XXXMicroprocessor Test Passed

No action

 

 

089-XXX-XXXMicroprocessor failure

1. Microprocessor(s)

 

2.

System board

 

 

089-195-XXXMicroprocessor Test aborted by user

Information only Restart the test, if necessary.

 

 

 

089-196-XXXMicroprocessor test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

089-197-XXXMicroprocessor test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

089-198-XXXMicroprocessor test aborted

1. Flash the system. See “Updating (flashing) the

 

 

BIOS” on page 165.

 

2.

Go to “Undetermined problems” on page 67.

 

 

089-199-XXXMicroprocessor test failed, cause unknown

1. See “Undetermined problems” on page 67.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Replace component under function test.

 

 

170-000-XXXVoltage Sensor(s) Test Passed

No action

 

 

170-0XX-XXXVoltage Sensor(s) failure

1. Flash system

 

2.

System board

 

 

170-195-XXXVoltage Sensor(s) Test aborted by user

Information only Restart the test, if necessary.

 

 

 

170-196-XXXVoltage Sensor(s) test halt, error threshold

1.

Press F3 to review the log file.

exceeded

2.

Restart the test to reset the log file.

 

 

 

170-197-XXXVoltage Sensor(s) test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Re-run test.

 

3.

Replace the component that is called out in warning

 

 

statement.

 

4.

Replace the component under test.

 

 

170-198-XXXVoltage Sensor(s) test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using

 

 

the Setup Utility program” on page 39.

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) the BIOS” on page 165.

 

3.

Go to “Undetermined problems” on page 67.

 

 

 

60Hardware Maintenance Manual

Page 66
Image 66
Lenovo 4222, 4220, 4215, 4219, 4221 manual Diagnostic Error Code, FRU/Action, See “Undetermined problems” on page